Download Print this page
Emerson Penberthy Multiview Installation, Operation And Maintenance Instructions
Emerson Penberthy Multiview Installation, Operation And Maintenance Instructions

Emerson Penberthy Multiview Installation, Operation And Maintenance Instructions

Top mount magnetic gage

Advertisement

Quick Links

PENBERTHY MULTIVIEW™ TOP MOUNT MAGNETIC GAGE
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be read fully and understood
TABLE OF CONTENTS
Product warranty ................................................ 1
1
Introduction .................................................. 1
1.1 Theory of operation ................................ 1
1.2 System description ................................ 1
2
Specifications ............................................... 2
2.1 General ................................................... 2
2.2 Floats ...................................................... 2
3
Installation .................................................... 2
3.1 Unpacking ............................................... 2
3.2 Assembly ................................................ 2
3.3 Installation .............................................. 3
3.4 Indicator alignment ................................ 3
4
Start-up ........................................................ 3
5
Periodic maintenance .................................. 3
6
Troubleshooting ........................................... 4
7
Telephone assistance .................................. 4
PRODUCT WARRANTY
Emerson warrants its Penberthy products as
designed and manufactured to be free of defects
in material and workmanship for a period of one
year after the date of installation or eighteen
months after date of manufacture, whichever is
earliest. Emerson will, at its option, replace or
repair any products which fail during the warranty
period due to defective material or workmanship.
Prior to submitting any claim for warranty
service, the owner must submit proof of purchase
to Emerson and obtain written authorization to
return the product. Thereafter, the product shall
be returned to Emerson, with freight prepaid.
This warranty shall not apply if the product has
been disassembled, tampered with, repaired
or altered outside of the Emerson factory, or
if it has been subjected to misuse, neglect or
accident.
Emerson's responsibility hereunder is
limited to repairing or replacing the product
at its expense. Emerson shall not be liable
for loss, damage or expenses directly or
indirectly related to the installation or use
of its products or from any other cause or
for consequential damages. It is expressly
understood that Emerson is not responsible
for damage or injury caused to other products,
building, property or persons, by reason of the
installation or use of its products.
valves.emerson.com
This is Emerson's sole warranty and in lieu of
all other warranties, expressed or implied which
are hereby excluded, including in particular all
warranties of merchantability or fitness for a
particular purpose.
This document and the warranty contained
herein may not be modified and no other
warranty, expressed or implied, shall be made
by or on behalf of Emerson unless made in
writing and signed by the company's general
manager or director of engineering.
1 INTRODUCTION
The Penberthy Multiview
top mount magnetic
gage (TMMG) is designed for applications
requiring visual indication but with the only access
being a single manway in the top of the vessel.
1.1 Theory of operation
The Multiview
TMMG tracks the liquid level
in a process vessel or tank by means of a float
located in the vessel. The float is connected
to a tube. At the opposite end of the tube is
a magnet. The magnet is contained in the
standpipe mounted to the vessel connection.
As the float level changes, so does the position
of the magnet. The level change is visually
conveyed to the operator via the indicator
mounted to the standpipe.
Point level control and remote continuous
level measurement are also available. This is
achieved by attaching electronic switches and/
or a 4-20 mA level transmitter to the exterior of
the communicating chamber.
1.2 System description
The Penberthy Multiview™ TMMG unit consists
of three major sections:
Standpipe chamber
The standard chamber consists of 1" Schedule
10 pipe constructed of 304/304L STS,
316/316L STS, Alloy 20, Monel or Hastelloy-C.
Other chamber materials such as Inconel 625
and Titanium may also be used.
Float
The float is constructed of 316L STS, Titanium,
Alloy-20, Monet, Hastelloy-C or Inconel 625.
© 2017 Emerson. All Rights Reserved.
Indicator
The indicator consists of a series of magnetically
interlocked flags. The flags are black on one
side and gold colored on the other. As the float
rises the flags rotate 180°, changing from black
to gold. Gold denotes where liquid exists, black
where it does not.
VCIOM-03390-EN 17/05

Advertisement

loading

Summary of Contents for Emerson Penberthy Multiview

  • Page 1 Before installation these instructions must be read fully and understood TABLE OF CONTENTS Indicator This is Emerson's sole warranty and in lieu of all other warranties, expressed or implied which The indicator consists of a series of magnetically Product warranty ..........1 are hereby excluded, including in particular all interlocked flags.
  • Page 2 PENBERTHY MULTIVIEW TOP MOUNT MAGNETIC GAGE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 2 SPECIFICATIONS 2.1 General Indication length: Standard range: 24" to 140" Operating temperature: (subject to indicator limitations) Standard flag indicator, hermetically sealed flag indicator, or follower indicator 750°F [399°C] Electronic switches/transmitter: Refer to the corresponding Installation, Operation and Maintenance manual for these items.
  • Page 3 PENBERTHY MULTIVIEW TOP MOUNT MAGNETIC GAGE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS 3.3 Installation 4 START-UP 1. A minimum distance of 8" should be maintained from the centerline of the 1. Check the connections between the standpipe to the nearest source of communicating chamber and the vessel to ferromagnetic material.
  • Page 4 (R. A.) number from Penberthy distributor, or call the factory direct Emerson prior to returning your unit. Failure (956) 430-2500 and ask for an applications to do so will result in the unit being returned engineer.