Gas filter
Change the gas filter when it is dirty.
Combustion
In case the combustion values found at the beginning of the inter-
vention do not respect the standards in force or, in any case, do not
correspond to a proper combustion, contact the Technical Assist-
ant and have him carry out the necessary adjustments.
6.2.3
Maintenance of burner electrical components
under the control box
To carry out in case of possible regulations and maintenance to the
underlying control box parts.
Proceed as follows:
 unscrew completely the screw 1)(Fig. 41);
 loosen the three screws 2) and lift the control box as indicated
by the arrows.
View A
3
20044771
Maintenance
1
2
3
D12186
The screws 3) move inside the slide until reaching the correct po-
sition indicated in "View A".
Fix the screw 3) backwards to the end in order to
adjust and maintain in complete safety.
WARNING
 At the end of maintenace loosen the screws 3), and lower the
control box, see "View B";
 fix the three screws 2) and screw the screw 1) in order to
tighten the control box to the burner.
2
2
3
34