Electrical Connection - HBM C16i Series Mounting Instructions

Digital load cell
Hide thumbs Also See for C16i Series:
Table of Contents

Advertisement

Available languages

Available languages

C16i...
9

Electrical connection

Position the load cell cable so that any condensation water or moisture form-
ing on the cable can drip off. It must not be routed to the load cell. In addition,
make sure that no dampness can penetrate the open end of the cable.
Furthermore, the cable must be placed such that the cable sheath suffers no
damage, e.g. from potential abrasion because of the load cell's propermotion.
Electrical and magnetic fields often are the cause for the introduction of dis-
turbing voltages into the measuring circuit.
Therefore:
D Use shielded low-capacitance cable only (HBM cables meet these
requirements)
D Do not lay the measuring cables in parallel to power cables, especially
high-tension and control lines. If this is not pssible, use steel conduits, for
example, to protect and shield the measuring cables
D Avoid the stray fields resulting from transformers, motors and contactors
A1461--1.2 de/en/fr
29
HBM

Advertisement

Table of Contents
loading

This manual is also suitable for:

C16i d1C16i c3

Table of Contents