Gree GWH18QD-K6DNA1C Series Service Manual page 85

Table of Contents

Advertisement

(11)
Troubleshooting
for F0 malfunction
Heat exchangers are
too dirty or the air inlet/outlet
is blocked.
No
Compressor doesn't work
normally. Strange noise or leakage occurs.
Casing is too hot.
No
System is blocked inside
(dirt block, ice block, oil block, Y-valve no
fully open).
No
The refrigerant is leaking
No
Replace a main
board with the
same model.
End
82
Clean the heat exchangers
and remove
Yes
blockage of air inlet/outlet.
No
Make compressor run normally.
Yes
No
Yes
Remove blockage in the system
No
Check the leaking status of refrigerant
Yes
and charge refrigerant
No
Malfunction is
Yes
eliminated.
Malfunction is
Yes
eliminated.
Malfunction is
Yes
eliminated.
Malfunction is
Yes
eliminated.
Installation and Maintenance
Service Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gwh18qd-k6dna3c seriesGwh18qd-k6dnb2c seriesGwh18qd-k6dnd4c seriesGwh18qd-k6dne6c seriesGwh18qd-k6dnc2c seriesGwh18qd-k6dne4c series ... Show all