About these instructions

1. About these instructions
Fold out the left-hand cover. This shows all the operating
elements and connections. Leave the cover folded out while
reading further.
Technical terms are explained in the glossary (Page 12).
Legend for fold-out page
Fig. 1
Scope of delivery
Fig. 2
Opening housing
Fig. 3
Display and operating elements
Number
Labelling
(1)
Power
(2)
(3)
(4)
Mode
(5)
(6)
(7)
1...8
(8)
Fig. 4
Connections
Number Function
(9)
I/O connector
(10)
Switch for setting normally open/normally closed
(11)
Slot for expansion module HCS 80
(12)
Connector for supply voltage, pump
(13)
Fuse
(14)
Slot for internal antenna
(Z1 - Z8) Connector for Zones 1...8
Fig. 5
I/O connector
Fig. 6
Connector for Zones 1...8
Fig. 7
Connector for supply voltage, pump

2. General safety instructions

DANGER
Danger to life through electric
shock!
Contacts that are open are live.
► Unplug the power plug before open-
ing the housing.
,
► Have all the work carried out by
authorised specialist personnel.
► Observe the valid VDE regulations
during the installation.
WARNING
Damage to the underfloor heating
controller!
Short-circuiting through humidity and
moisture.
► Mount the device at a site that is
protected against humidity and mois-
ture.
4
Function
Power supply on/off
Information display
Installation display
Operating mode button
Installation button
Pump on/off display
Zone LEDs
Labelling of Zones 1...8

3. Overview

The floor hearing system is an intelligent system for individ-
ual room temperature control. The following overview shows
devices that can operate together with the underfloor heat-
ing controller.
(A)
(B)
(E)
(I)
(J)
(I)
A Setpoint adjuster HCW 82
Controls the setpoint temperature for each temperature
zone via adjustment dial
B Central operating device CM67z
Controls the room temperature via programmable time
programs
C Room temperature sensor HCF 82
Transmits room temperature information to underfloor
heating controller
D Hometronic Manager HCM 200D
Central operating unit of the house-automation system
E Underfloor heating controller
HCE 80/HCC 80/HCE 80R/HCC 80R
Controls actuators; communicates with setpoint adjusters
and room temperature sensors
F Boiler feedback,
Analog output (only HCE 80/HCC 80) or
Relay output (only HCE 80R/HCC 80R)
G Integrated pump relay
H Thermal actuators
I
External antenna HCE 80/HCE 80R
Internal antenna HCC 80/HCC 80R
J Boiler feedback relay HC60NG/R6660D
(C)
(D)
(F)
(G)
(H)