13.7. Brief instructions

► Specify which heating circuits are to be controlled
by the underfloor heating controller.
See Section "Creating a zoning plan", Page 5.
► Mount the required components.
A Setpoint adjuster HCW 82
Controls the setpoint temperature for each temperature
zone via adjustment dial
B Central operating device CM67z
Controls the room temperature via programmable time
programs
C Room temperature sensor HCF 82
Transmits room temperature information to underfloor
heating controller
D Hometronic Manager HCM 200D
Central operating unit of the house-automation system
E underfloor heating controller
HCE 80/HCC 80/HCE 80R/HCC 80R
Controls actuators; communicates with setpoint adjusters
and room temperature sensors
F Boiler feedback,
Analog output (only HCE 80/HCC 80) or
Relay output (only HCE 80R/HCC 80R)
G Integrated pump relay
H Thermal actuators
I
External antenna HCE 80/HCE 80R
Internal antenna HCC 80/HCC 80R
J Boiler feedback relay HC60NG/R6660D
See Section "Installation", Page 5.
► Set the underfloor heating controller to the corresponding
thermal actuator (normally open or normally closed), cable
the connections and interconnect the components.
See Section "Installation and configuration", Page 6.
► Assign the room temperature sensors, setpoint adjusters and
other control components to the temperature zones (teach-in).
If you use time programs:
► Assign room names at the Hometronic Manager, if applicable.
► Assign a time program of the CM67z to the temperature
zones, if applicable.
See Section "Commissioning", Page 8.
13.7.1.

Navigation and function overview

Function
Press button
Normal mode
-
Teach-in
> 2 s
Delete allocated
Mode > 4 sec in
devices
teach-in mode
Device display
Keep
for < 2s
Mode > 4 s
Cooling mode
Press
in order to acti-
vate/de-activate
cooling mode
Status LED
LED flashes yellow
LED lights up
yellow
LED lights up
yellow
LED flashes yellow Red = Room actual value
pressed
LED green = Cool-
ing mode active
button
LED red = Cooling
mode inactive
(A)
(B)
(E)
(I)
(J)
(I)
Zone LED
Lights up green = Valve open
LED off = Valve closed
Flashing
Zone LED extinguishes
Green = Time program
Yellow = Room actual value/time
program
Red = Cooling active and cool-
ing contact open
(Class 3 and 4)
Green = Cooling active and
cooling contact closed
(Class 3 and 4)
Appendix
(C)
(D)
(F)
(G)
(H)
Exit mode
Allocate device
(e.g. HCW 82)
4 min after last action
4 min after last action
• Automatically after 60 s
or
• Press other button
• Automatically after 60 s
or
• Press Mode button
15