Tighten locking screw [10-1] (Torx TX20) with max. 1 Nm while holding
down button

10. Troubleshooting

Malfunction
Fluttering/Spitting
spray fan or air bub-
bles appearing in the
gravity flow cup
Air bubbles appearing
in the gravity flow cup
Air bubbles appearing
in the gravity flow cup
Spray pattern is too
small, crooked, lop-sid-
ed or splitting
Round/flat fan control
cannot be regulated
Cause
Fluid tip has not been
properly tightened
Loose air cap
Gap between air cap
and fluid tip ("air cir-
cuit") is clogged
Nozzle set is clogged
or damaged
Not enough paint ma-
terial in the gravity flow
cup
Defective paint needle
sealing
Clogged air cap drill-
ings
Damaged fluid tip (fluid
tip aperture)
Regulation valve dirty
Corrective action
Tighten fluid tip [2-1]
Tighten air cap [2-2]
by hand
Clean air circuit, ob-
serve chapter 8
Clean nozzle set,
chapter 8, or replace,
respectively, chapter
9.1
Refill gravity flow cup
[1-6]
Replace the paint nee-
dle sealing, chapter
9.3
Clean air cap, observe
chapter 8
Check if fluid tip is
damaged, replace the
nozzle set, if neces-
sary, chapter 9.1
Remove round/flat
fan control, restore
to working order or
replace completely,
chapter 9.6