Fault
The vacuum suddenly
Clogged primary filter
stops
Motor protector tripper
Clogged suction pipe
Dust leaks from the
The filter is torn
vacuum
Inadequate filter
The vacuum blows
Incorrect connections to
instead of sucking
the mains socket
Electrostatic current on
Non existent or
the vacuum
inefficient earthing
14
Causes
Remedies
Shake the filter. Replace
it if this is not sufficient
Check the setting.
Check the suction pipe
and clean it.
Check the power draw of
the motor. Contact an
authorized after-sales
service centre if
necessary
Change it for another of
identical category.
Change it for another of
suitable category and
check.
Check all earth
connections. Particularly
check the suction inlet
fitting.
Remove the plug and
invert two of the live
wires.
Lastly, the pipe must
strictly antistatic
32401106(1)2004-04 A