Technical Data; Maintenance; Foreword; Checks And Inspections On Start-Up - Nilfisk-Advance IV 055 Instructions For Use Manual

Table of Contents

Advertisement

Available languages

Available languages

TECHNICAL DATA

Model
IV 055
A [mm]
1,520
B [mm]
770
C [mm]
1,650
Weight [kg]
315
Description
IV 055
Voltage range [V]
3x200-415
Rated power [W]
5,500
Protection grade
IP55
(dust, moisture)
Insulation class
F
(Electrical)
Dust class
L, M, H
Airflow [L/sec]
165
Vacuum (Max) [kPa]
47
Vacuum at
continuous service
28
[kPa]
Suction power [W]
1,580
Sound pressure level
at 1.5m
74.6
[db(A)/20uPa]
Size (H x L x W) [cm] 167x152x77 174x165x77 174x165x77 174x165x77
Weight [kg]
315
Container volume [L]
130
Cable length [m]
9.5
2
Main filter area [cm
]
36,500
Absolute filter type
105,000
2
HEPA [cm
]
32401106(1)2004-04 A
IV 075
IV 110
IV 150
1,650
1,652
1,650
770
770
770
1,740
1,740
1,740
375
383
428
IV 075
IV 110
IV 150
3x200-415
3x200-415
3x200-415
7,500
11,000
15,000
IP55
IP55
IP55
F
F
F
L, M, H
L, M, H
L, M, H
205
205
335
47
49
45
28.5
30
30
1,865
2,000
2,670
76
75.4
78.6
375
383
428
150
150
150
9.5
9.5
9.5
36,500
36,500
36,500
105,000
105,000
105,000
INSTRUCTIONS FOR USE

MAINTENANCE

Foreword

ATTENTION!
All maintenance and cleaning operations
must be carried out when the vacuum is off
and disconnected from the mains socket.
The suction unit needs no particular maintenance or
lubrication.
Remember, however, that correct use and servicing are
essential if the safety and efficiency of the vacuum are to
be guaranteed.
To ensure regular and constant operation and to prevent
the warranty from becoming void, only ever use genuine
Nilfisk-Advance A/S spare parts when replacements are
needed.

Checks and inspections on start-up

The customer should proceed with the following
inspections to ensure that the vacuum has not been
damaged during transportation.

Before starting

Check that the mains voltage value corresponds to that for
which the machine is preset.
Check that all warning and danger plates are affixed and
legible.
Check that all protections are installed and efficient.

With the vacuum operating

Check that all the air seals are perfectly tight.
Check that all fixed protections are efficient.
Proceed with suction tests using the same materials used
during work.
This will ascertain whether all parts of the vacuum operate
correctly.

Routine maintenance

Strictly comply with the following operations to ensure that
the vacuum remains in a constantly reliable condition.
11