4. MAINTENANCE
4.3

Troubleshooting

The troubleshooting table below provides typical operating problems and the means
to restore normal operation. If you cannot restore normal operation, do not open the
cover of the FA-40; there are no user serviceable parts inside the receiver.
Symptom
Cannot turn on the pow-
er.
Cannot receive.
ERROR LED lights in
red.
ERROR LED lights in or-
ange.
Cannot start the AIS Set-
ting Tool, or cannot con-
nect the PC to the
receiver.
No position data (when
optional GPS antenna
unit is connected).
AIS Receiver FA-40
The FA-40 has no power switch. Power is fed from the ship's switchboard, and a pow-
er switch on the switchboard turns the FA-40 on or off.
The table below shows the function for each LED.
LED
POWER
ERROR
RX
POWER LED
• Memory error
• RX1/2 PLL unlock error
4-2
• Check the cable between the receiver and power for
damage.
• Check the power supply.
• Check the fuse.
• Check that the VHF antenna cable is firmly connected.
• Check the VHF antenna and its cabling for damage.
• Confirm the channel setting.
Contact your dealer.
Check that the optional GPS antenna is correctly connect-
ed.
• Check the USB cable between the receiver and the PC
for damage.
• Do the following:
1) Quit the AIS Setting Tool.
2) Disconnect the USB cable from the PC, and then con-
nect the cable again.
3) Start the AIS Setting Tool.
• Check the GPS antenna.
• Check the GPS antenna cable and its connectors.
Color
Green
When the power is on, the POWER LED lights in green.
Red
The ERROR LED lights in red when equipment error (RX,
ROM, or RAM) is found.
Orange
The ERROR LED lights in orange when the equipment is not
installed correctly.
Green
The RX LED lights in green for 50 msec when receiving.
POWER -
Red
Remedy
Meaning
ERROR LED (See the table below.)
- ERROR
- RX
RX LED
Orange
GPS antenna short