Input:polarity - VXI VM4016 User Manual

Vxi analog comparator user's manual
Table of Contents

Advertisement

INPUT:POLARITY

The input polarity command selects the input polarity for one or more channels. When a channel
is programmed for normal polarity, an interrupt will be generated when the input voltage is
greater than the programmed input offset for the channel. The invert polarity will cause an
interrupt when the input voltage is less than the programmed input offset for the channel.
INPut:POLarity <polarity>,<channel_list>
EXAMPLES
INPut:POLarity NORM,(@3:5)
INPut:POLarity? 5
NORM
INP:POL INV,(@6)
30
VXI Technology, Inc.
Where <polarity> is either NORMal or
INVerted
Where <channel_list> is the standard
channel list format supporting channels 1
through 16.
Sets the input polarity for Channels 3
through 5 to NORMal. This will generate an
interrupt when the input signal on Channels
3, 4, or 5 is greater than the input offset.
Returns the input polarity for Channel 5 as
NORMal
Sets input polarity for Channel 6 to invert.
VM4016 Programming

Advertisement

Table of Contents
loading