Displaying The Barcode Data - IDEC HG2F-SS22VF Manual

Connect an operator interface to a barcode reader
Table of Contents

Advertisement

4. Description of the Program
4-2 Displaying barcode data
"Message Display" is a screen that is available with the operator interface is used for displaying the
barcode data. A Message Display is capable of displaying text data (ASCII or Shift-JIS code) in the
operator interface and PLC or other devices.
On the Program screen in this example, READ DATA and STORED DATA can be displayed.
The following section describes the setting procedure using WindO/I-NV2.
(1) Select the "Message Display" icon from the toolbar.
Set up the STORED DATA display using a similar procedure.
Reference Device: "LKR 100"
Words:
* The descriptions for the "View" and "Format" settings are omitted in this text. For these descriptions,
refer to the section "Parts" in Chapter 5 "Draw and Parts Objects" in the Instruction Manual.
(6) When the settings of step (1) through (4) are
complete, click the [Set] button. The specified
display appears in the "Ch1" column of the
Variable field.
"7"
(2) Enter "\@" to display a variable
message.
(3) Select "Ch1".
(4) Designate the Reference Device
setting to "LDR 8010".
(5) To display 13-digit data in this sample,
designate "7". (2-digit data is stored in
1 word.)
(7) Click the [OK] button.
13