6-2 Adjusting the needle entry point
○ Remove the face cover.
Adjustment procedure
1. Select the straight stitch using the pattern selecting button. Choose center needle position.
2. Assemble a needle #14 into the needle bar, loosen the setscrew in the eccentric collar and adjust the feed
bar eccentric collar so that the needle meets the center of the needle slot in the throat plate when it reach-
es the top surface of the throat plate by turning the hand wheel.
Setscrew
Feed bar eccentric collar
– 15 –