ABB M25102xC Series Manual page 52

Outdoor station
Table of Contents

Advertisement

ABB-Welcome
1 #
=>
2 #
2.
Modify the "system password"
#* system password #
2 #
=>
Enter new password (6-8 bits) #
3.
Modify the "door open code"
#* system password #
3#
=>
Enter new door open code (6-8 bits) #
4.
Setting the voice message
If the audio module with the speech synthesis function (M251024A-.) is assembled,
the local language can be set.
#* system password #
4#
=>
Press
5.
Enable/disable the access control function
Enable access control function:
#* system password #
5#
=>
1 #
Disable access control function:
#* system password #
5#
=>
2 #
*Reset the system password of keypad module:
It is possible to reset the system password to factory-setting if you have forgotten it.
The restoration of default factory settings does not delete the rest of the
information programmed on the system, such as user names and other settings.
1.
Disconnect the power supply.
2.
Reconnect the power
Hold the "program button" for 5s within 30s.
3.
A "di" will be sounded and the system password will be reset to the default
4.
(345678).
Pos : 21 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/83220-AP- xxx/Bedi enelemente - 83220- AP- xxx @ 18\mod_1303212853605_15.doc x @ 103673 @ @ 1
2149 @ @ 1
|
=>
=>
=>
or
to choose the language
=>
=>
=>
Enter the password again #
=>
Enter the code again #
=>
#
Operation
— 52 —

Hide quick links: