Installation
Checking the installation niche
Check the installation dimensions
(see "Installation – Installation dimen-
sions").
Check the position of the electrical
connection. The length of the elec-
trical connection cable is 3 m.
The electrical socket must not be
concealed behind the appliance and
must be easily accessible in an
emergency.
Check the position of the fresh water
connection. The available length of
the stainless steel hose is approx.
2 m.
The stopcock must not be concealed
behind the appliance and must be
easily accessible in an emergency.
28
Check the surroundings for possible
collisions (see "Installation – Dimen-
sions with appliance door open").
Only install the refrigeration appliance
in stable, solid installation niches, po-
sitioned on an even and level floor.
Also check the installation niche for
the following criteria:
- The side walls of the installation
niche must be even.
- The surrounding walls of the installa-
tion niche must be at least 16 mm
thick.
- The surrounding walls must be se-
curely fixed to the floor or wall.
- Shortened side walls must be at least
100 mm deep.