Led Displays; Simolink Encoder Status - Siemens SIMOVERT MASTERDRIVE SLE Operating Instructions Manual

Simolink-encoder
Table of Contents

Advertisement

Available languages

Available languages

Start-Up
6.2

LED displays

6.2.1

SIMOLINK Encoder status

NOTE
LED
POWER
SYNC
l
l
l
l
l
l
l
LED off
l
LED illuminated continuously
LED flashing (approximately twice per second)
6-6
02.2001
The status of the SIMOLINK Encoder as regards SIMOLINK addressing
and pulse outputs is indicated via three green LEDs on the front panel.
The status of the SLE-DP encoder module can also be read out via the
PROFIBUS (cf. Section 6.4.6).
SIMOLINK ENCODER
SLE
Fig. 6-2
Description
Z-Pulse
Device not connected to supply voltage
No + 24 V supply voltage available
Supply voltage connected:
SYNC interrupt is not being received
DIL switch is incorrectly set:
Address switch is outside permissible range, SYNC and
Z-Pulse LEDs are flashing synchronously
SIMOLINK cycle time is not defined:
SYNC interrupt is outside 1.6 / 3.2 ms cycle
(251/502 telegram times, dispatcher mode)
SYNC interrupt is being received in the correct cycle:
SIMOLINK Encoder has not been activated or
setpoint telegram is not being received or
pulse output is not enabled via the control bit or
speed setpoint = 0 is being transmitted
l
Device is outputting signals
Z-PULSE LED is flashing in synchronism with zero pulse (appears
to be illuminated steadily at high speeds)
Table 6-5
SIMOLINK Encoder operating states
SLE / SLE-DP – SIMOLINK Encoder
SIMOLINK ENCODER SLE-DP
GWE-477 763 4070.76 J
Operating Instructions