SLE / SLE-DP – SIMOLINK Encoder
6.1.3

Bottom DIL switch S3

NOTICE
Siemens AG
GWE-477 763 4070.76 J
SIMOVERT MASTERDRIVES
02.2001
The node address of the SIMOLINK Encoder is set via DIL switch S3.
Switch
Designation
0
S3.1
2
1
S3.2
2
2
S3.3
2
3
S3.4
2
4
S3.5
2
5
S3.6
2
6
S3.7
2
7
S3.8
2
Table 6-4
Meaning of DIL switch S3
The SIMOLINK Encoder returns its internal pulse counter actual value
plus a status bit "STATUS-SLE" via SIMOLINK. It writes this to its
actual-value telegram that is defined by the send address
(= node address) and channel address (= 0, fixed setting).
If the SIMOLINK Encoder is activated even though the node address is
incorrectly set (i.e. 0 or >200), then '1' is transferred as the node
address, i.e. the SIMOLINK Encoder writes to the telegram of the node
with address '1'.
Operating Instructions
Meaning
SIMOLINK Encoder node address
Note:
S3.1 is the least significant bit
Start-Up
Range
1...200