Leveling kit, 2010 and after multi-pro turf sprayers and workman 200 spray system
Table of Contents

Advertisement

G017151
Uncovered boom configuration shown
1. Cover
2. Sensor
3. Large nut
4. Lower sensor housing
5. Install the programming plug on the sensor
(Figure 11).
Important: Ensure that you align the arrow
below the sideways "T" with the notch on the
top edge of the sensor (Figure 11).
1
2
6
7
8
Figure 10
5. Cap tube
6. Bolts (5/16 x 1-1/4 inch)
7. Locknuts (5/16 inch)
8. Finished sensor assembly
3
4
3
5
1. Sideways "T"
2. Arrows aligned
6. Insert the sensor into the lower sensor housing, and
secure it with 2 large nuts provided with the sensor
(Figure 10).
Note: Discard the lock washers that come with the
sensors.
7. Install the cap tube and the cover (Figure 10).
Note: Ensure that the sensor wire is routed through
the small opening in the cover before installing the
sensor cover.
8. Secure the wire coming from the sensor to the boom
with cable ties.
Important: Ensure that you allow enough slack
in the wire around the sensor so that the sensor
can freely pivot on the hinge without pulling on
the wire.
9. Repeat the steps above for the other boom.
Note: For covered booms only: The sensors should
not detect the boom cover as this may interfere with
the signal. If you experience any difficulties during the
calibration process, check the sensors to ensure that
their signals do not detect the boom cover.