multiple
times
Bag
Use the included belt bag to protect the Distance Meter when not
in use.
Errors
A faulty measurement or result is indicated by the display "InFo
nnn" [3, 4] and a long signal tone. Possible causes may be:
InFo Cause
156 Lateral inclination
>10º
204 Data overflow
205 Measurement outside
the range
206 Logical error
252 Temperature
is too high
253 Temperature
is too low
255 Received signal too
weak
256 Received signal too
strong
38
measuring function.
The contents of the display are cleared in the
following order: [4] – [3] – [2].
Remedy
Reduce the inclination about the
longitudinal axis
Repeat the work steps.
Adhere to the permissible measure-
ment range of the Distance Meter.
An arithmetic operation is not possi-
ble. For example, you are attempting
to add values that have different units
of measurement.
Allow the Distance Meter to cool
down. Operate the Distance Meter
only within the permissible tempera-
ture range.
Take the Distance Meter to an envi-
ronment that has a higher tempera-
ture and allow it to warm up. Operate
the Distance Meter only within the
permissible temperature range.
Avoid surfaces that do not reflect well
or not at all. Look for a measuring
point with stronger reflection.
Avoid highly reflective or shiny surfac-
es. Look for a measuring point with
less reflection.
LDM 500-80
+
© KALEAS GmbH & Co. KG
ENGLISH