Maintenance; Accessories; Spare Parts - WOHLHAUPTER DigiBore 501 Series Operating Instructions Manual

Precision boring tool
Table of Contents

Advertisement

Available languages

Available languages

of preventing coolant from entering the
battery compartment. Only batteries with
the following specification must be used
for operating this precision tool:
VARTA V392 SR 41 Sil ver oxide / Zinc /
KOH-Electrolyte. Only these batteries
have been tested in relation to the high
centrifugal forces involved. To change
the batteries, open the battery compart-
ment
3
(Figure 10). Use a Torx T 20 ser-
vice key to open the unit, remove the old
batteries and dispose of them correctly.
Close the battery compartment again
carefully.
Description of the metric display
1
Battery charge display (Low battery)
2
+/– sign
3
Decimal comma
4
Value displayed in mm
Description of the inch display
1
Battery charge display
(Low battery)
2
– sign
5
Comma for inch display
6
Value displayed in inches
4 6
1
2
3
5
Fig. 11

5. Maintenance

The tool needs only to be cleaned after
use and the serrated body lightly grea-
sed. To keep the tools in top class con-
dition and maintain their value, store
them in a dry place and occasionally
cover them with a light film of oil.

6. Accessories

The accessories are not included in the
equipment supplied and must be orde-
red separately.
You can obtain the latest information
on accessories from the Wohlhaupter
product catalogue as well as from the
website: www.digibore.de

7. Spare parts

215 674
Threaded taper pin for
mounting accessories
415 353
Clamping screw for slide
clamping
415 896
Battery (always change
2 batteries)
501 016
Battery access cover
with sealing ring
415 895
Sealing ring for battery cover
115 576
Hexagon wrench SW 4
215 150
Service Key T20