Installation Instruction - Vinotemp WINE-MATE VINO1500HZD Use And Care Manual

Wine-mate cooling unit
Hide thumbs Also See for WINE-MATE VINO1500HZD:
Table of Contents

Advertisement

Select a place to mount the unit where the exhaust airflow is unobstructed for a
minimum of 6 inch. The area into which the unit exhausts must be well ventilated.
If it is not, heat exhausted by the unit will build up and the unit will not operate
properly. The ambient temperatures shall not be higher than 78
1500HZD unit and 95
supply air from the front grille must remain unobstructed. The unit shall be
mounted near the ceiling with equal distance from each side of the cabinet or
room.
The cooling unit produces cooling supplied into the cabinet, and it also generates
heat that must be exhausted outside the cabinet. So the cold supply side and hot
exhaust side must be separated and sealed. Foam tape may be used to seal
them. The cooling unit must intake adequate fresh ambient-air to work properly.
The ambient-air intake and warm-air exhaust must not be short-circulated. A
piece of wood may be used to separate them.
NOTES:
1) DO NOT INSTALL ANY DUCTS ONTO THE SUPPLY, INTAKE AND
EXHAUST.
2) MOUNTING BRACKETS, SCREWS, GASKETS AND OTHER SEAL
MATERIALS ARE NOT INCLUDED.
1. VINO1500-2500HZD CABINET INSTALLATION
• Cut a rectangular inside opening with the 1/4" clearance inwards to the
width and height of the cooling unit. By not going through, leave 1/2" lip
inside at the wall to place the gaskets (see Fig 2.1 & 2.2).
• If top exhaust, cut another rectangular opening at the top of the cabinet to
the length and width of the top exhaust.
• Make 2 holes at the ceiling to install the 1/4 inside diameter wood thread
inserts (see Fig.2.1 & 2.4).
• Place the gaskets (1/2" foam tape) on the mounting lip sides (see Fig 2.2).

Installation Instruction

°
F for the other units or lower than 50
- 5 -
°
F for a VINO-
°
F. Additionally, cold

Hide quick links:

Advertisement

Table of Contents
loading