Repeater Information; Repeater Configuration; General Parameters - Viking 242-2009-632 Service Manual

900 mhz ltr-net 75w-160w repeater
Table of Contents

Advertisement

LTR-Net PROGRAMMER

4.3.3 REPEATER INFORMATION

This menu selection has an equivalent icon in the toolbar. This menu selection or icon brings up the
parameter pages for the selected repeater. It allows entry of information specific to this repeater.
Repeater Number
1-20
Channel Number
1-399
Receive Frequency
Transmit Frequency
Test Mode ID
1-239
Local Mic ID
1-239
Status Free
0=never
20=always
RNT Link
None
FSK
Dig
BnB
RF Power Level
Low, High
Options
Stand Alone
High Stability Synth Selected if the Receiver and Transmitter use the High Stability Synthesizer.
Allow LTR
Status Channel
Alarm to CIB
HSDB All Data
Xmit Channel Info
Power Source
AC, DC
CWID Time
0=disabled, 1-30 min The time interval between CWID transmissions.
CWID Message
Station call letters
OK
Cancel
Help
March 1999
Part No. 001-2009-600
Figure 4-9 REPEATER CONFIGURATION
Table 4-3 GENERAL PARAMETERS
Repeater number was established in Locality Configuration.
Channel number was established in Locality Configuration.
Frequency was determined by channel number in Locality Configuration.
Frequency was determined by channel number in Locality Configuration.
Group ID transmitted when the Repeater is in the Test Mode.
Group ID transmitted when the local microphone PTT is active.
When the number of free channels falls below this value, Status Channel can be
used for voice.
Data Signaling type for 3000 Series Switch.
Frequency Shift Keying
RS-232
Blank and Burst (FSK)
Low=25-75, High=75-160. Power level in watts for transmit power output.
Selected if the repeater is permitted to operate without a connection to the 3000
Series Switch.
Selected if standard LTR protocol is allowed.
One repeater at a Locality is designated to transmit update information for all
calls occurring at that Locality. Normally not assigned as a Home repeater.
Routes repeater alarms to the Channel Interface Bus to be detected by the Call
Processor and the System and Subscriber Manager.
Repeater receives all the data on the High Speed Data Bus.
Repeater sends updates on all repeaters installed in this Locality.
The type of primary power source for the Repeater.
This is the FCC station call letters (15 characters/numbers).
Saves the current selections shown and closes the window.
Disregards all changes on any of these four screens and closes the window.
Displays the Help screen for the parameters in this window.
4-4

Advertisement

Table of Contents
loading

This manual is also suitable for:

242-2009-634

Table of Contents