2.9 REPEATER DATA BUS INSTALLATION

The repeaters are interconnected by a balanced
line High-Speed Data Bus (HSDB) consisting of a six
conductor cable. The total length of the HSDB cannot
exceed 500 feet. Connect the cables in daisy-chain
fashion to modular connector A5 on the back of the
repeater (see Figure 2-16). A 50 ohm termination is
not required for VIKING VX repeaters.

2.9.1 MPC DATA BUS SWITCH SETTINGS

Switch settings on the MPC for the two types of
installations require S2 and S3 sections to be switched
as indicated in Figure 2-5.
ONLY VIKING VX REPEATERS
(CENTER REPEATERS)
S3
2
1
3
4
ON
ONLY VIKING VX END REPEATERS
S3
2
1
3
4
ON
1 2 3 4
Figure 2-5 MPC DATA BUS SWITCHES
March 1999
Part No. 001-2009-600
RECEIVER
MULTICOUPLER
Figure 2-4 5-CHANNEL COMBINING SYSTEM
S2
2
3
4
5
6
7
8
1
ON
2
3
4
5
6
7
8
1
ON
1 2 3 4 5 6 7 8
T/R ANTENNA
DUPLEXER
TRANSMITTER
BANDPASS
FILTER
COMBINER
PREAMPLIFIER

2.9.2 MPC DATA BUS JUMPER SETTINGS

Refer to Figure 2-6 for crystal selection and
HSDB Code selections jumper placement. Jumper
J5, pins 1-2 selects 11.059 MHz for LTR-Net (J5, pins
2-3 selects 12 MHz crystal for Standard LTR). The
jumper on J4, pins 5-6 connects EPROM U14, pin 27
to ground for LTR-Net (J4, pins 3-4 connects EPROM
U14, pin 27 (A14) to +5V for Standard LTR single-
ended 5V data bus).
CRYSTAL SELECTION
J5
HSDB CODE SELECTION
J4
Figure 2-6 MPC JUMPERS
Jumper J4 must be placed with the following
guidelines: J4, pins 5-6 for operation with the RJ-11 to
RJ-11 cable 200X systems (see Section 4.5.6).
2-6
TRANSMITTER 1
TRANSMITTER 2
TRANSMITTER 3
TRANSMITTER 4
TRANSMITTER 5
1
2
3
2
4
6
1
3
5

Advertisement