2.6.1 AC INPUT REQUIREMENTS

AC Input Voltage:
Line Frequency:
AC In-rush:
Overall Efficiency:
Lightning protection:
Power Factor:
Brown Out Voltage:
Temperature
Power factor correction per IEC555. The Power
supply has the following safety agency approvals
pending: UL1950, CSA22.2-950, TUV EN60950
(IEC950)
When the AC input voltage is below 90V AC, the
maximum output power is decreased to keep the input
current constant. If a battery back-up is installed, the
batteries take over when the AC input voltage falls
below 80V AC (dependent on power output).
The AC input connector is an IEC connector
equipped with a locking mechanism.
BACKPLANE
1
4
7
2
5
8
3
6
9
J2
A
2
4
1
10
7
3
5
11
8
B
6
12
9
C
POWER CABLE CONNECTOR AND SCHEMATIC
100-240V AC
50-60 Hz
60A maximum
>70% at 100V AC
>80% at 240V AC
6kV for < 1ms
>0.97 at full load
80V AC
-30°C - +60°C (full power)
POWER HARNESS
J2
+26.5V
A
GROUND
TO
B
RFIB
+15V
C
1
2
3
AC FAIL IN
4
2
POWER SWITCH
5
1
THERMAL SENSOR
6
4
N/C
7
5
+15V
8
3
N/C
9
9
N/C
10
6
+5V
11
8
-5V
12
7
The operating temperature range is -30°C to
+60°C (-22°F to +140°F), i.e. the same as the repeater.
The fan is thermostatically controlled by the internal
temperature. When the internal heatsink temperature
reaches +45°C (113°F) the fan turns on. When the
heatsink temperature drops below +35°C (95°F) the
fan turns off. If the internal heatsink temperature
reaches +90°C (+194°F) the power supply turns off
until the heatsink temperature drops below +85°C
(+185°F). The over-temperature shutdown and restart
are automatic.

2.7 GROUNDING

PROPER SITE GROUNDING AND LIGHTNING
PROTECTION ARE VERY IMPORTANT TO PRE-
VENT PERMANENT DAMAGE TO THE REPEATER.
As in any fixed radio installation, measures
should be taken to reduce the possibility of lightning
damage to the Viking VX equipment. Proper ground-
ing eliminates shock hazard, protects against electro-
magnetic interference (EMI) and lightning.
2-3
INSTALLATION
TO
REPEATER
BACKPLANE
CAUTION
March 1999
Part No. 001-2009-600