Check, Adjust The Valve Clearance - Fayat Group Bomag BPR 70/70 D Operating And Maintenance Instruction Manual

Reversible vibratory plate
Hide thumbs Also See for Bomag BPR 70/70 D:
Table of Contents

Advertisement

Fig. 51

6.8.2 Check, adjust the valve clearance

Maintenance – Maintenance every 6 months
After each charging process allow the battery to rest for one
hour before taking it into service.
For resting periods of more than one month you should
always disconnect the battery. Do not forget to perform reg-
ular open-circuit voltage measurements.
NOTICE!
Exhausted batteries (batteries with formation of
sulphate on the plates) are not covered under war-
ranty!
Open the hood.
Unscrew bracket (1) Ä Fig. 51 of the battery.
Remove the vibration insulation mat (3).
Remove the battery (2) and clean the battery compartment.
Clean the outside of the battery.
Clean battery poles and pole clamps and grease them with
pole grease (Vaseline).
Check the condition of the vibration insulation mats, replace if
necessary.
On serviceable batteries check the acid level, if necessary
top up to the filling mark with distilled water.
Install battery and vibration insulation mats.
Fasten the bracket again.
Close the hood
NOTICE!
We recommend to have this work carried out by
trained personnel or our after sales service.
Check and adjust only when the engine is cold.
The gasket for the cylinder head cover must be
generally renewed.
Valve clearance:
BPR 70/70 D
63

Hide quick links:

Advertisement

Table of Contents
loading