Sensor Modules - Siemens SINUMERIK 828D Training Manual

Machine commissioning
Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

Hardware information
Sensor Modules (SMC & SME)
General.
Sensor modules are required to convert non-DriveCliq encoder signals into
DriveCliq signals.
They are available for cabinet mounting (SMC) and external mounting (SME)
Several variants of each are available:-
SMC10/SMC20
SMC10
For the evaluation of 2-pole resolvers & Multi-pole resolvers, including motor
temperature evaluation (KTY84-130)
Interfaces:-
X500 DriveCliq.
X520 Measuring system input (25 pin D-type connector)
X524 24V DC supply
Status LED's
Part Number:-
6SL3055-0AA00-5AA0
SMC20
For the evaluation of the following measuring systems:-
Incremental sin/cos 1v pp
Absolute EnDat encoders
SSI with incremental signals Sin/Cos 1V pp
(Temperature evaluation-KTY84-130 can also be used)
Interfaces:-
X500 DriveCliq.
X520 Measuring system input (25 pin D-type connector)
X524 24V DC supply
Status LED's
Part Number:-
6SL3055-0AA00-5BA1