Reed Instruments R9030 Instruction Manual

Hardness tester
Hide thumbs Also See for R9030:

Advertisement

Quick Links

R9030
Hardness Tester
Instruction
Manual
REED Instruments
1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R9030 and is the answer not in the manual?

Questions and answers

Summary of Contents for Reed Instruments R9030

  • Page 1 R9030 Hardness Tester Instruction Manual REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 2: Table Of Contents

    Impact Direction ................11 Average ..................11 Material ..................12 Hardness Scale ................12 Tolerance Limit ................12 Hard/ b (Hardness/Strength Testing) .......... 13 Probe Type ................... 13 Standard ..................13 Memory Manager ................13-15 continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 3: Introduction

    Product Disposal and Recycling .............. 23 Product Support ..................23 Introduction Thank you for purchasing your REED R9030 Hardness Tester. Please read the following instructions carefully before using your instrument. By following the steps outlined in this manual your meter will provide years of reliable service.
  • Page 4: Product Quality

    • Rechargeable lithium battery • Low battery indicator Included • D Impact Device • Leeb Test Block • Small Supporting Ring • Nylon Brush • AC Adapter • USB Cable • Software • Hard Carrying Case REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 5: Specifications

    32 to 104°F (0 to 40°C) Storage Temperature: -4 to 140°F (-20 to 60°C) Operating Humidity Range: 0 to 90% Dimensions: 5.7 x 1.3 x 1" (146 x 32 x 26mm) Weight: 5.6oz (160g) REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 6: Instrument Description

    1. Support Ring 2. LCD Display 3. POWER/Exit Button 4. Menu/Enter Button 5. Measurement set up shortcut/Right/Down/Increase Button 6. Scan/Delete/Left/Up/Decrease Button 7. Micro USB Port 8. Impact Device 9. Coding Sheath 10. Release Button REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 7: Display Description

    Connection Flag: The connection flag will blink when the instrument is trying to connect to the PC. A solid flag means successful connection. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 8: Hardness Testing Principle

    When the curvature radius (R) of the curved surface to be tested is less than 30mm (for D and DL type impact device), a small support ring (included with the R9030) should be used. Self-magnetism of the test piece should be less than 30 Gauss.
  • Page 9: Prior To First Measurement

    The distance of two indentation center and impact device indentations center edge of test piece D, DC, DL, D+15 No less than: 3mm No less than: 5mm No less than: 2mm No less than: 4mm continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 10: Viewing Measurement Values

    Menu Navigation/Setup Mode Press the button to enter the menu screen. Press the buttons to scroll through the following parameters. Parameter Description Test Set Setting up your meter Memory Manager View/Delete/Transfer Data continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 11: Test Set

    "Average" is highlighted. Press the buttons to select the number of measurements to be used to calculate the average value between 1 and 32. Press the button to confirm selection. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 12: Material

    Press the button to confirm and skip to the next digit. After each value has been selected and confirmed, it will automatically exit the "Tolerance Limit setup" screen. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 13: Hard/ B (Hardness/Strength Testing)

    Delete By No. Delete All Follow the instructions below to adjust each setting. Note: If there is no data in the memory, it will display "No Memory!", and return to the menu screen. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 14: View From No.1/View From End

    Press the button to confirm and skip to the next digit. After each value has been selected and confirmed, the meter will ask to confirm deletion of the specific groups. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 15: Delete All

    Enabling/Disabling Auto Transfer Press the button to turn Auto Transfer On or Off. Press the buttons to skip to the next parameter when complete. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 16: Enabling/Disabling Auto Shutoff

    (Average). Press the button to select the number of measurements to be used to calculate the average value between 1 and 32. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 17: Calibration Procedure

    Measurement data stored in the memory of the gauge can be transferred to the computer through the micro-usb port. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 18: Launching The R9030 Software

    Launching the R9030 Software Visit www.reedinstruments.com/software & drivers to download the R9030 software. Double click on the software labeled DV-R9030 located in the REED Hardness Tester Dataview folder to launch. If the meter fails to connect, it may require that the driver be installed separately.
  • Page 19: Applications

    • In locations with difficult access, or in confined spaces Appendix A: Hardness Scale Tables The R9030 includes D impact device. Please note that impact devices DL, DC, D+15 and C can be ordered seperately. For more information please contact us at 1-877-849-2127 or info@REEDinstruments.com.
  • Page 20 6HLD D (included) 530±40HLD ±10HLD 10HLD 760±30HLDC ±6HLDC 6HLD DC (optional) 530±40HLDC ±10HLDC 10HLD 878±30HLDL DL (optional) ±12HLDL 12HLDL 736±40HLDL 766±30HLD+15 D+15 (optional) ±12HLD+15 12HLD+15 544±40HLD+15 822±30HLC C (optional) ±12HLC 12HLC 590±40HLC continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 21 85~655 85~802 Gray Cast Iron 93~334 Nodular Cast 131~387 Iron 19~164 23~210 Cast Aluminum Alloys 23.8~84.6 22.7~85.0 40~173 Brass (Copper- Zinc Alloys) 13.5~95.3 Bronze (Copper-Aluminum/ 60~290 Copper-Tin Alloys) Wrought Copper 45~315 Alloys continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 22: Accessories And Replacement Parts

    To clean the guide tube, unscrew the support ring and then take out the impact body. Use the nylon brush to clean in a counter-clock direction. Repeat this 5 times and remount the impact body and the support ring. continued... REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...
  • Page 23: Product Warranty

    REED Instruments guarantees this instrument to be free of defects in material or workmanship for a period of one (1) year from date of shipment. During the warranty period, REED Instruments will repair or replace, at no charge, products or parts of a product that proves to be defective because of improper material or workmanship, under normal use and maintenance.
  • Page 24 TEST & MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS! REED Instruments 1-877-849-2127 | info@reedinstruments.com | www.reedinstruments.com...

Table of Contents