Connections for a debugging network
2
Create settings for the development PC.
Start the DHCP client software and set up the
development PC in advance to obtain the IP
address and other settings from the DHCP
server. For information on operating the
software and obtaining the IP address, refer to
the instruction manual for the development PC.
3
Create settings for the DHCP server.
When obtaining the IP address from the DHCP
server, the assigned IP address usually differs
each time. Using a static IP address will
facilitate operating the unit. To set a static IP
address, contact the network administrator.
Confirming the settings information
After connecting the host PC and the AV MULTI
480i- or HDMI 480p-compatible display, turn on
the reference tool and the system.
1
Turn on the main power switch
(t page 14).
This turns on the unit and starts system
initialization. During initialization, the status
indicator flashes green. This indicator stops
flashing when the initialization process is
complete.
Caution
Do not operate the unit during initialization.
2
Press the power button.
The power indicator will change from red to
green. After approximately 30 seconds, the
system will start up.
Caution
Do not operate while the system is starting up.
3
Confirm the information that is displayed.
Check that the following information is
displayed:
• IP address
• Subnet mask
• Broadcast address
• IP address for the default gateway
• MAC address
• Host name
24
Connections for a debugging network
Settings information appears on the display in
the following cases:
• When the main power switch is on
• When network information is changed by the
administration tool
• When the IP address has been restored to the
factory default setting
• When the system of the communication
processor has been restored to the factory
default settings
• When the administration tool's "Restart of
dtnem" command has been executed
Caution
• To restore the system of the communication processor to
the factory default settings, while holding down the
system initialise button, press the power button.
• Under the factory default settings, the AV MULTI 480i-
or HDMI 480p setting is used. To restore the factory
default settings after video settings have been adjusted,
press and hold the power button for more than 5 seconds
to start the system.
• To restore the IP address to the factory default setting,
while holding down the network initialise button, press
the power button.
Adjusting network settings
For details on adjusting network settings, see
"Setting up with the administration tool" >
"Network" (t page 30).