Technical specifications
ZAPTECH HOME is an alternating current
charging station for wall or column installation
in accordance with IEC 61851-1, EVSE mode 3.
Dimensions and weight
H: 392 mm. W: 258 mm, D: 1 12 mm Weight:
approximately 5 kg (including back panel)
Installation network
TN, IT and TT
Installation circuit
Max. 40 A series connected fuse in the
charging station installation circuit.
Max. 3 x ZAPTEC HOME connected in one
installation.
Transition box/fuse box
The charging point must be protected against
overvoltage in accordance with NEK-400
Junction box
Cable cross-section 2.5-10 mm²
Cable diameter 10-20 mm²
Installation network, Voltages
230VAC ±10% 400VAC ±10%
Max. power and charging output
7.36kW* at 32A/1-phase
22kW* at 32A/3-phase (applicable to TN
networks only)
* output is controlled by how many devices
are charging and may depend on the internal
temperature of the charging station.
Charging connector
EC 62196-2 Type 2 Female, silver
plated for durability
Earth fault protection
Built-in RCD type B
Calibration and self-testing are performed
before the start of each charging cycle. The
earth fault protection is automatically reset
when the charging cable is disconnected.
Integrated power meter
Integrated in the charging station with an
accuracy of +/- 1% for power and voltage. This
allows the user to monitor and verify the actual
power consumption.
Theft protection
The front cover can only be opened using
specialist tools. The charging cable can be
permanently locked to the charging station.
Phase distribution
Depending on installation and vehicle type the
charging station can switch between 1-phase
and 3-phase charging station mode. If two or
three charging stations are used, the phase
usage will be coordinated in the optimal
manner.
Avoid uneven load - When the charging station
operates in 1-phase mode, it can dynamically
select which of the three phases to use for
charging. The charging station can also be
programmed to use a specific phase if required.
Load distribution
The available power in the installation is
automatically distributed between up to three
charging stations and the home (APM).
Communication interface and cloud
connectivity/network
4G LTE-M1 (subscription required)
Wi-Fi 2.4 GHz, IEEE 802.1 1 b/g/n (channels
1-1 1)
Identification and configuration via app
and charging tag
Bluetooth Low Energy (BLE 4.1)
RFID/NFC reader
Standards and approvals
CE conformity in accordance with the Radio
Equipment Directive 2014/53/EU and ROHS
Directive 201 1/65/EU. Conforms with IEC
61851-1 and IEC 61851-22
Temperature range
-30°C to +50°C
Degree of protection
IP54, indoor and outdoor use IK10 shock