Menu / Query Parameters

1. On main interface screen, press
buttons to navigate to each parameter. Refer to table below for a list of all parameters.
DOWN
(DEFROST)
2. Press
at any time to confirm settings and go back to main interface.
ON/OFF
(UNLOCK)
Code
Parameter Name
A1
Coil temp
A2
Compressor suction
gas temp
A3
Compressor exhaust
gas temp
A4
Ambient air temp
A5
Outlet water temp
A6
Compressor current Displays the compressor current (3-Phase
A7
Opening of the EEV
E1-E6
Error code display
to enter into parameter query menu. Press
MENU
(SET)
Description
This is the evaporator coil temperature.
This is the refrigerant gas temperature at the
inlet of the compressor.
This is the refrigerant gas temperature at the
outlet of the compressor.
This is the ambient (atmospheric) tempera-
ture.
This is the water temperature at the outlet of
the heat pump (return to pool).
units only).
Opening angle of the EEV (Electronic Expan-
sion Valve).
Displays up to 6 error codes, in the unlikely
event or malfunction. Refer to Troubleshoot-
ing section for error code details.
Page 21
Configuration
and
UP
(HEAT/COOL)
Typical Range
(-10)-15
C (Heat)
0
35-48
C (Cool)
0
(-10)-15
C (Heat)
0
10-25
C (Cool)
0
40-80
C (Heat)
0
60-95
C (Cool)
0
(-10)-45
C
0
5-40
C
0
5-10A
10-60
None