Separatesensorfor flexible installation 3 different sensor models for standard focus, narrow focus and fine spot measurement thermo-hunter built-in2

Advertisement

THERMO-HUNTER
Non-Contact Thermometer
BUILT-IN2
Separate Sensor
BS Series
SPECIFICATIONS
Sensor head
Model
Field of view
Optics
Sensing element/Wavelength
Sighting method
Ambient temperature
(0 to 150˚ C : with optional cooling jacket)
Environmental humidity
Storage temperature
Vibration resistance
Water resistance
Weight
Optional accessories
* A sensor and an amplifier form one complete set.
They do not function individually.
* Specifications may change without prior notice.
DIMENSIONS
• Sensor Head
BS-30T/BS-05T
BS-02T
Laser hole
• Amplifier
BS-A/BS-V
Connector
Ring
92
45
11
40
Screw holes
M4 8mm depth
• Sensor Mounting Bracket (option)
NB-SH30A
(for BS-30/05T)
2-
9
64
42
2
30
12.5
84
28
2-
9
84
BS-30T
BS-05T
ø30/500mm
ø5/100mm
Silicon lens
Thermopile/8 to 14m
N/A (Use BS-LD for sighting)
0 to 65˚ C
35 to 85%RH (without dew condensation)
–20 to 70˚ C
3G (20 — 50Hz, in accordance with JIS C0911)
IP67
300g
400g
Refer to the Optional Accessory Table of the previous page
Connector cable
Cable length
124
2000 50
Caution label
Connector cable
Cable length
2000 50
104
Amplifier Fixture
W1/4 Tap
52
40
6
6
Cover
2-R6
Model ID
2m Cable
NB-SH40A
(for BS-02T)
2-
11
90
60
3
45
15
114
2-
11
114
Amplifier
BS-02T
Model
ø2/50mm
Measuring range
Display range
Response time
Coaxial laser marker
Accuracy (
1.0)
(Class 2)
Repeatability
0 to 50˚ C
Display resolution
Analog output
Output resolution
–20 to 60˚ C
Emissivity ratio ( ) adjustment
Delay setting
Power supply/Current consumption
Ambient temperature
Environmental humidity
Storage temperature
Vibration resistance
Water resistance
Weight
Standard accessories
• Air/Water Cooling Jacket (option)
BS-WP1
(for BS-30/05T)
Mounting fixture
Products mentioned in this catalogue are equipped with Class 2 laser.
In case of re-export to foreign countries, please confirm the relevant requlation for laser products
in the destination country.
31
Do not look into the laser or direct it toward the eyes. Even the
WARNING
reflection is harmful. Laser may cause eye injury or damage
your health.
This product is not a clinical thermometer; therefore,
CAUTION
it cannot be used for medical purposes.
KEEP THE THERMOMETER AWAY FROM DIRECT SUNLIGHT, DUST, HIGH TEMPERATURES
AND HIGH HUMIDITY WHILE IN USE AND STORAGE.
This may cause irreparable damage or incorrect measurement.
DO NOT EXPOSE THE THERMOMETER TO SUDDEN TEMPERATURE CHANGES.
Sudden temperature change of the environment may cause incorrect measurement. In such cases,
wait until the thermometer reaches steady temperature before taking measurement.
KEEP THE THERMOMETER AWAY FROM STRONG ELECTROMAGNETIC SOURCES,
CORROSIVE OR EXPLOSIVE GASES.
This may cause irreparable damage or incorrect measurement.
AVOID MEASURING SHINY SURFACES.
Shiny surfaces reflect radiation from surrounding objects. Although the emissivity ratio can be adjusted
to compensate for this problem, accurate measurement is difficult.
USE THE CORRECT VOLTAGE.
Applying voltages other than 12-24VDC may cause short-circuit, damages, fire or injury. In such cases,
turn the power off immediately.
DO NOT LET THE THERMOMETER TOUCH THE OBJECTS THAT IS BEING MEASURED.
36
The unit is a non-contact thermometer. Touching or getting too close to the objects with high
temperatures may cause irreparable damage or incorrect measurement.
DO NOT TOUCH THE LENS.
Do not touch the lens with anything hard or things with sharp points, which may dameage the lens. A
damaged lens causes incorrect measurement.
KEEP THE THERMOMETER AWAY FROM CHARGED OBJECTS.
This may cause irreparable damage or incorrect measurement.
U K A S
P.O.Box 24009, 2490 AA The Hague, The Netherlands
QUALITY
MANAGEMENT
TEL +31 (0)70 4194100 FAX +31 (0)70-3177321
001
E-mail: info@optex.nl
BS-V
BS-A
0 to 500˚ C
–20 to 520˚ C
500msec./90%
1% of reading value or 2˚ C whichever is greater
1˚ C of reading value
1˚ C
1mV/˚ C
0.2˚ C
0.10 to 1.20 (0.01/1 step)
1 (0.5sec) to 200 (approx. 10sec) variable
DC12 — 24V 10%/Max 100mA
0 to 50˚ C
35 to 85%RH (without dew condensation)
–20 to 60˚ C
3G (20 — 50Hz, in accordance with JIS C0911)
IP65
320g
Fixture x 1, M4 screw x 2
3.2
150
45
48
18
14
60
12.5
16
2-R3
Air feeder (PF1/8)
2- 6
Safety Guidelines
CAUTION
DO NOT STARE INTO BEAM
LASER DIODE POWER MAX 1.0mW
WAVE LENGTH670nm
CLASS2 LASER PRODUCT
Environmental Warnings
Usage Warnings
Website: www.optex.nl
No. 74040-02-09785-0009
4 — 20mA
[Unit: mm]
Water outlet (PF1/8)
Water inlet (PF1/8)
BS-02T and BS-LD
are Class 2 laser
products.

Advertisement

loading

This manual is also suitable for:

Bs-30tBs-05tBs-02tBs-aBs-v