Self-Diagnostics

When an RCP-750/751 remote control panel or the RM-
B750 is connected to the CCU-590/590P, or when a switch
on the internal IV board is set, you can display the results
of self-diagnostics of the internal boards of the CCU-590/
590P and other information on a monitor screen.
When the RM-B750 is connected to the CCU-590/590P,
the information can be viewed on the monitor connected to
the PIX or VBS/SDI-3 connector.

Settings of the camera

Press the CHARACTER button on the RCP-750/751
remote control panel or the RM-B750 while the status of
the CCU-590/590P is displayed on the monitor screen.
The settings on the video camera appears.
At the top of the screen, the following items are displayed
from left to right: MASTER GAIN, CROP, EVS,
SHUTTER, and SHUTTER ON/OFF.
At the bottom of the screen, the following items are
displayed from left to right: ND FILTER, IRIS,
EXTENDER, and CC FILTER.
For the meanings of each item, refer to Operation Manuals
of the video camera.

Status display of the camera system

Press the CHARACTER button on the RCP-750/751
remote control panel or the RM-B750 while the video
camera status is displayed on the monitor screen. The
status of the camera system appears.
12
Self-Diagnostics
BVP (the first column): Model name and format of the
connected camera
CCU (the second column): Model name and format of
the connected camera control unit
GEN Lock: The status of the external reference signal
Prompter: Transmission direction of the teleprompter
signal
Dsub15pin: Microphone input level setting performed
through the MIC REMOTE connector
Return-1 to 4: The settings of the RET-1, RET-2/
PROMPTER, SDI RET-3/RET-4 connectors
Self-diagnostics of the camera
system
Press the CHARACTER button on the RCP-750/751
remote control panel or the RM-B750 while the status of
the CCU-590/590P is displayed on the monitor screen. The
results of a self-diagnosis of the camera system are
displayed. Press the CHARACTER button again to display
successive pages.
Page 1
TRIAX TYPE: Type of Triaxial circuit
TRIAX Cable: Triax cable connection status (connected/
disconnected)