Pressing Product-L soft key from "Select
Setup Option" screen opens "Enter Product
Length and press Save key" screen. The
following choices are displayed:
Automatic – Allows Tabber to automatically
measure and set piece length. It is highly
recommended that you use Automatic to
verify proper media feeding and sensing.
IMPORTANT: Before pressing
Automatic soft key, make sure Feeder is
turned OFF and Tabber's transport power
switch is turned ON
BACK – Returns to previous screen.
When Automatic soft key is pressed, display
may prompt you to "Increase Transport
Speed" or "Decrease Transport Speed".
Adjust transport speed until display shows
"Feed 1 Product now".
When display reads "Feed 1 Product
now", feed one of your mail pieces
through Tabber.
NOTE: Feeding more than one mail piece
will cause an incorrect length to be
measured and set.
After piece is fed through Tabber, Tabber will
stop and display piece length.
Verify measurement!
It must be accurate (+ or - 0.250").
If Tabber measures piece to be longer than the actual piece length; then media may be slipping or
hesitating as it feeds. Check/Adjust transport system.
If Tabber measures piece to be shorter than the actual piece length; then media may not be
feeding straight (missing Sensor), or a hole in media may be traveling through Sensor, or Sensor
may be getting reflection off mail piece. If using a high gloss media, sensor intensity may need
to be adjusted lower by a qualified service person.
If media passes through without Tabber providing a measurement, Media Sensor may be dirty.
Try cleaning Sensor as described in this manual. These problems need to be corrected before
Tabber will function correctly.