Poor lift
Pump has no
performance
resistance, lift ram
will not raise to full
stroke
Will not lift
Lift ram has limited
to full
stroke, pump loses
extension
resistance
Fluid level low
Air trapped in system
Fluid level low
Made in China to TQB Brands Pty Ltd specifications
Visit us at www.tqbbrands.com.au
Fill fluid to correct level
Lift ram raised for
extended period causing
air ingress to hydraulic
system
Lift ram raised for
extended period causing
air ingress to hydraulic
system
BTSJ20TB
Fill fluid to correct
fluid level and bleed
system
With ram fully
retracted, remove oil
filler plug to let
pressurised air
escape
reinstall oil filler plug
then bleed system
Fill fluid to correct
level then bleed
system