3. SPECIFICATIONS

Power Supply
Input Voltage
Input Current
Input Connection
Input Purge Gas
Gas Input Connection
Operating Temperature
Operating Humidity
Operating Distance*/
Voltage
Length
Width
Height
Weight
Mounting Hardware
Enclosure
Compliance
*Note: the operating distance set for the bar in the Control Station must be the same as the mounting
distance bar to web. This is critical for accurate calibration.
IQ Easy Sensor Bar
IQ Power Control Station
24 VDC
0.05A +0.022A/sensor
5-pin M12 (A-coded) female receptacle
1 to 2.5 psi (7 to 17 kPa) nominal operating pressure
5 psi (35 kPa) max operating pressure
0.14 scfm (4 NL/min) per sensor at 1 psi (5 kPA)
0.22 scfm (6 NL/min) per sensor at 2.5 psi (20 kPa)
Clean, dry, oil-free compressed air or nitrogen
¼" OD Tubing, Quick Disconnect
122˚F [50˚C] max
70% RH, no dewing permissible (max)
2" (50 mm) 20 kV max
3" (75 mm) 25 kV max
4" (100 mm) 30 kV max (factory default setting)
6" (150 mm) 40 kV max
8" (200 mm) 50 kV max
10" (250 mm) 60 kV max
13.14" (334 mm) to 157.23" (3994 mm)
1.19" (30 mm)
1.71" (44 mm)
0.9 lb/ft (1.3 kg/m)
Polyamide bracket, zinc plated metal perforated strip, stainless steel
hardware
Glass fiber reinforced polyester, conductive polyamide
RoHS
4
5201226 Rev. F