Download Print this page

Operation - Victron energy Phoenix VE.Direct 12 | 250 Manual

Hide thumbs Also See for Phoenix VE.Direct 12 | 250:

Advertisement

Available languages

Available languages

4. Operation

4.1 LED definitions
Green LED
●●●●●●●●
Solid on
●●------
Slow single pulse
●-●-----
Fast double pulse
--------
Off
Red LED
●●●●●●●●
Solid on
●●●●----
Slow blink
●-●-●-●-
Fast blink
●-●-----
Double pulse
●---●---
Fast single pulse
6
Status
Trouble shooting
Inverter on
Red LED Off
status OK
Red LED On or blinking:
The Inverter is still on, but will shut down when the
condition gets worse. See red LED table for warning
reason
ECO mode
If the inverter keeps switching on and off while there is a
load connected, the load may be too small compared to the
actual ECO mode settings. Increase the load or change
ECO mode settings. (minimum ECO mode setting: 15 W)
Off and waiting Inverter did shut down because of a protection. The
inverter will restart automatically as soon as all alarm
conditions are cleared. See red LED state for the shutdown
reason.
Inverter off
Red LED Off
Check the On/Off/ECO switch: it should be in On position
or in ECO position.
Check Remote on/off connector.
Check DC cable connections and fuses.
Inverter fuse blown: the inverter has to be returned for
service.
Red LED On or blinking
The inverter did shut down because of a protection. It will
no longer automatically restart. The red LED indicates the
reason for shutdown. Remove the cause and then restart
the inverter by switching it Off, and then back On.
Definition
Trouble shooting
Overload
Reduce load
Low batt.
Recharge or replace battery
Check DC cable connections
Check cable cross section as it may be insufficient.
See section 4.3 Protections and automatic restarts for
manual and automatic restart behavior.
High batt.
Reduce DC input voltage, check for faulty charger
High temp.
Reduce load and/or move inverter to better ventilated area
High DC ripple Check DC cable connections and cable cross section.

Advertisement

loading