Optional Top Vent Application

The DVBR36/42 fireplace is shipped as a rear vent unit.
If the layout requires a top vent, convert the unit follow-
ing the steps below.
DVBR36
1. Remove the eight (8) screws securing outer collar
adapter to fireplace. (Be careful not to damage insu-
lation.) (Fig. 10)
2. Set outer collar adapter aside.
Remove
Screws (4)
Outer Collar
Adapter
Flue Pipe
Remove Screws (4)
Fig. 10 Remove screws from outer collar adapter.
3. Remove insulation on top of collector box. (Fig. 11)
4. Remove the four (4) screws securing flue cover to
top of unit and remove flue cover. (Fig. 11)
5. Remove the four (4) screws securing flue pipe to
back of unit. Remove flue pipe. (Fig. 11)
Flue
Cover
Flue
Pipe
Remove Screws
(4)
Fig. 11 Remove flue cover and flue pipe.
20000584
Rear View
DVT584-602
DVT584-602
Outer Collar Adapter
Flue Pipe
3/11/99 djt
Insulation
Remove
Screws (4)
DVT584-603
DVT584-603
Outer Collar Adapter
Flue Pipe
3/11/99 djt
DVBR Series Direct Vent Gas Fireplace
6. Secure flue cover to back of flue outlet. Be sure to
replace gasket. (Fig. 12)
7. Install flue pipe to top of unit with four (4) screws. Be
sure to replace gasket. (Fig. 12)
8. Set insulation in back of unit foil side down.
9. Secure outer collar adapter to unit with the round
collar on top, secure with eight (8) screws.
NOTE: Be sure not to damage any gasket material.
Flue Pipe
Flue
Pipe
Insulation
Fig. 12 Replace flue cover and flue pipe.
Fig. 13 Completed conversion.
Replace
Screws (4)
Replace
Screws
(4)
Foil Side
DVT584-604
DVT584-604
Outer Collar Adapter
Flue Pipe
3/11/99 djt
DVT584-605
DVT584-605
Outer Collar Adapter
Flue Pipe completed
3/11/99 djt