Parts Identification And Chase Installation; Gas Line Installation - Majestic fireplaces NVBC42 Homeowner's Installation And Operating Manual

Decorative gas appliances
Table of Contents

Advertisement

NVB Series B-Vent Gas Fireplace
(Insulation methods shown are optional for cold climate,
not a requirement for unit operation.)
Batt Insulation
(cut out around
firestop)
Firestop
Ceiling Level
Nailing Flange
Electrical Access
Outside Air Cover Plate
Fig. 7 Parts identification and system installation.

Gas Line Installation

This appliance must be isolated from the gas supply
piping system by closing its individual manual shut off
valve during any pressure equal to or less than 1/2 psig
(3.45 kPa).
The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psig (3.45 kPa).
If gas piping from the source to the appliance location
has not been accomplished, install the required pipe.
Consult local plumbing code to assure proper pipe size.
8
Parts Identification and Chase Installation
WF597
NVC (from FP528)
12/2/97
Termination Cap
Storm Collar
Pan Flashing
Draftstop
Standoff
Surround
Screen
Grate
Firebox
The gas pipeline can be brought in through the right
side of the appliance. A knockout is provided to al-
low for the gas pipe installation and testing of any gas
connection. It is most convenient to bring the gas line
in from the right side, as this allows fan installation or
removal without disconnecting the gas line.
NOTE: The gas line connection can be made with 3/8"
copper tubing approved for propane or natural gas, 1/2"
rigid pipe or an approved flex connector, then reduced
to 3/8" to the appliance. Because some municipalities
have some additional local codes, it is always best to
consult your local authority.
*Do not install header
until unit is in place.
See Page 8, "Mounting
the Appliance."
FP597
7412950