Overload Indicator Light (Red); Reset Button; Fuel Tank Cap Air Vent Lever - Yamaha EF2200iS Owner's Manual

Hide thumbs Also See for EF2200iS:
Table of Contents

Advertisement

1
3
4

Overload indicator light (Red)

The overload indicator light comes on when electricity
over the rated output is required by the connected elec-
trical devices, or when the inverter control unit over-
heats, or the AC output voltage rises. Then the AC
protector will trip, stopping power generation in order to
protect the generator and any connected electric
devices.
1. Overload indicator light (Red)
TIP
The overload indicator light may come on for a few sec-
onds at the first when using electric devices that
require a large starting current, such as a compressor
of a submersible pump. However, this is not a malfunc-
tion.

Reset button

If an overload has been detected, the circuit breaker
has activated, and the generator output has been
stopped, stop any connected electrical devices and
hold the reset button for 3 seconds.
The breaker will be reset and the output will resume.
1. Reset button
1

Fuel tank cap air vent lever

The fuel tank cap is provided with an air vent lever to
stop fuel flow.
The air vent lever must be turned to "ON" to run the
1
engine.
1. Air vent lever
2
2. Fuel tank cap
3. "ON"
4. "OFF"
"ON"
This will allow fuel to flow to the carburetor and the
engine to run.
"OFF"
When the engine is not in use, turn the air vent lever to
"OFF" to stop fuel flow.