Description
Hot water outlet of water tank
Circulating water inlet/outlet of water tank
Cooling water inlet of water tank
Pipe joint

18.3 Connection of waterway system

(1) ,I FRQQHFWLRQ EHWZHHQ ZDWHU WDQN DQG LQGRRU XQLW VKRXOG EH WKURXJK WKH ZDOO GULOO D KROH
circulating water pipe. It is unnecessary if the hole is not needed.
(2) Preparation of pipelines: Circulating water outlet/inlet pipe must be hot water pipe, PPR pipe with nominal
out diameter of dn25 and S2.5 series (wall thickness of 4.2mm) being recommended. Cooling water inlet
pipe and hot water outlet pipe of water tank should also be hot water pipe, PPR pipe with nominal out
diameter of dn20 and S2.5 series (wall thickness of 3.4mm) being recommended. If other insulated pipes
are adopted, refer to the above dimensions for out diameter and wall thickness.
(3) Installation of circulating water inlet/outlet pipes: connect the water inlet of the unit with circulating outlet of
water tank and water outlet of unit with circulating inlet of water tank.
(4) ,QVWDOODWLRQ RI ZDWHU LQOHWRXWOHW SLSHV RI WKH ZDWHU WDQN VDIHW\ FKHFN YDOYH ¿OWHU DQG FXWRII YDOYH PXVW EH
installed for the water inlet pipe according to the installation sketch of the unit. At least a cut-off valve is
needed for the water outlet pipe.
(5) Installation of blow-off pipes at the bottom of water tank: connect a piece of PPR pipe with drainage outlet
WR ÀRRU GUDLQ $ FXWRII YDOYH PXVW EH LQVWDOOHG LQ WKH PLGGOH RI WKH GUDLQDJH SLSH DQG DW WKH SODFH ZKHUH LW LV
easy to be operated by the users.
(6) After connection of all waterway pipelines, perform the leakage test firstly. After that, bind up the water
pipes, water temp sensor and wires with wrapping tapes attached with the unit.
(7) Refer to Installation Sketch of the Unit for details.
Indoor Unit
Other Thermal sensor (less than 5 meters)
Power cord of booster heater
Joints Dimension
Water Tank
Temp Sensor 1
Safety check
e
valv
Temp sensor
Cool Water
Inlet
Blow-off Outlet
33
Air-to-water Heat Pump Split Versati
Joint pipe thread
 )HPDOH %63
 )HPDOH %63
 )HPDOH %63
 )HPDOH %63
Hot water output
Othe r
Thermal
System
Filter
Tap water
2
 IRU SDVV RI