Gree Versati III Series Owner's Manual page 39

Air-to-water heat pump split
Hide thumbs Also See for Versati III Series:
Table of Contents

Advertisement

SPLIT
TYPE
 6SHFL¿FDWLRQ RI SRZHU VXSSO\ ZLUH DQG OHDNDJH VZLWFK
3RZHU FDEOH VSHFL¿FDWLRQV DQG /HDNDJH VZLWFK W\SHV LQ WKH IROORZLQJ OLVW DUH UHFRPPHQGHG
Model
GRS-CQ4.0Pd/NhH-E(O)
GRS-CQ6.0Pd/NhH-E(O)
GRS-CQ4.0Pd/NhH-E(I)
GRS-CQ6.0Pd/NhH-E(I)
GRS-CQ8.0Pd/NhH-E(O)
GRS-CQ10Pd/NhH-E(O)
GRS-CQ8.0Pd/NhH-E(I)
GRS-CQ10Pd/NhH-E(I)
Notes
(a) Leakage Switch is necessary for additional installation. If circuit breakers with leakage protection are in use,
action response time must be less than 0.1 second, leakage circuit must be 30mA.
(b) The above selected power cable diameters are determined based on assumption of distance from the
distribution cabinet to the unit less than 75m. If cables are laid out in a distance of 75m to 150m, diameter of
power cable must be increased to a further grade.
(c) The power supply must be of rated voltage of the unit and special electrical line for air-conditioning.
(d) All electrical installation shall be carried out by professional technicians in accordance with the local laws
and regulations.
(e) Ensure safe grounding and the grounding wire shall be connected with the special grounding equipment of
the building and must be installed by professional technicians.
(f) 7KH VSHFL¿FDWLRQV RI WKH EUHDNHU DQG SRZHU FDEOH OLVWHG LQ WKH WDEOH DERYH DUH GHWHUPLQHG EDVHG RQ WKH
maximum power (maximum amps) of the unit.
(g) 7KH VSHFL¿FDWLRQV RI WKH SRZHU FDEOH OLVWHG LQ WKH WDEOH DERYH DUH DSSOLHG WR WKH FRQGXLWJXDUGHG PXOWLZLUH
copper cable (like, YJV XLPE insulated power cable) used at 40℃ and resistible to 90℃ (see IEC 60364-5-52).
,I WKH ZRUNLQJ FRQGLWLRQ FKDQJHV WKH\ VKRXOG EH PRGL¿HG DFFRUGLQJ WR WKH UHODWHG QDWLRQDO VWDQGDUG
(h) The specifications of the breaker listed in the table above are applied to the breaker with the working
temperature at 40 ℃  ,I WKH ZRUNLQJ FRQGLWLRQ FKDQJHV WKH\ VKRXOG EH PRGL¿HG DFFRUGLQJ WR WKH UHODWHG
national standard.
(i) A circuit breaker must be added to the fixed line. The circuit breaker is all-pole disconnected and the
breaking distance of the contact is at least 3mm.
Leakage
Power Supply
Switch
V,Ph,Hz
(A)
230V,~,50Hz
230V,~,50Hz
35
Air-to-water Heat Pump Split Versati
Minimum Sectional
Area of Earth Wire
2
(mm
)
16
1.5
16
1.5
20
6.0
20
6.0
25
4.0
25
4.0
40
6.0
40
6.0
Minimum
Sectional Area
of Power Supply
Wire
2
(mm
)
1.5
1.5
6.0
6.0
4.0
4.0
6.0
6.0