Connection Of Waterway System - Gree Versati III GRS-CQ4.0Pd/NhG-K Owner's Manual

Hide thumbs Also See for Versati III GRS-CQ4.0Pd/NhG-K:
Table of Contents

Advertisement

Air-to-water Heat Pump
SXVD200LCJ/A-K
Model
SXVD200LCJ/A-M
SXVD200LCJ/A-H
Litre
coil specification
M
coil length
N
D(mm)
D1(mm)
H(mm)
A(mm)
B(mm)
C(mm)
E(mm)
F(mm)
I(mm)
J(mm)
K(mm)
Outline
(Diameter×H) (mm)
Package
(W×D×H) (mm)
Net weight
kg
Gross weight
kg
Description
Hot water outlet of water tank
Circulating water inlet/outlet of water tank
Cooling water inlet of water tank
Pipe joint

15.3 Connection of waterway system

(1) If connection between water tank and indoor unit should be through the wall, drill a hole φ70 for pass of
circulating water pipe. It is unnecessary if the hole is not needed.
(2) Preparation of pipelines: Circulating water outlet/inlet pipe must be hot water pipe, PPR pipe with nominal
out diameter of dn25 and S2.5 series (wall thickness of 4.2mm) being recommended. Cooling water inlet
pipe and hot water outlet pipe of water tank should also be hot water pipe, PPR pipe with nominal out
diameter of dn20 and S2.5 series (wall thickness of 3.4mm) being recommended. If other insulated pipes
are adopted, refer to the above dimensions for out diameter and wall thickness.
(3) Installation of circulating water inlet/outlet pipes: connect the water inlet of the unit with circulating outlet of
water tank and water outlet of unit with circulating inlet of water tank.
(4) Installation of water inlet/outlet pipes of the water tank: safety check valve, filter and cut-off valve must be
installed for the water inlet pipe according to the installation sketch of the unit. At least a cut-off valve is
needed for the water outlet pipe.
(5) Installation of blow-off pipes at the bottom of water tank: connect a piece of PPR pipe with drainage outlet
to floor drain. A cut-off valve must be installed in the middle of the drainage pipe and at the place where it is
easy to be operated by the users.
(6)
After connection of all waterway pipelines, perform the leakage test firstly. After that, bind up the water
pipes, water temp sensor and wires with wrapping tapes attached with the unit.
(7) Refer to Installation Sketch of the Unit for details.
SXVD200LCJ2/A-K
SXVD200LCJ2/A-M
SXVD200LCJ2/A-H
200L
200L
\
10m
13m
13m
540
438
1595
272
432
431
\
80
\
247.5
739
Φ540×1595
1623×628×645
68
71
77
80
Joints Dimension
SXVD300LCJ/A-K
SXVD300LCJ/A-M
SXVD300LCJ/A-H
300L
SUS304 Ф22X0.8
\
18.5m
105
112
\
\
82
92
Joint pipe thread
1/2"Female BSP
3/4"Female BSP
1/2"Female BSP
3/4"Female BSP
26
SPLIT TYPE
SXVD300LCJ2/A-K
SXVD300LCJ2/A-M
SXVD300LCJ2/A-H
300L
10m
18.5m
620
528
1620
280
464
399
95
202.5
718
Φ620×1620
1648×708×725
87
97