Wen 56380i Instruction Manual page 11

3800w inverter generator
Hide thumbs Also See for 56380i:
Table of Contents

Advertisement

KNOW YOUR INVERTER GENERATOR
CONTROL PANEL
MULTI
100%
50%
0%
VOLTAGE FREQUENCY TIME
VOLTAGE FREQUENCY TIME
LOAD
15
3. AUTO OFF
14
1. Multimeter with Indicator Lights
2. Reset Button
Push button to reset the circuit (see page 21)
3. AC 120V NEMA 5-20 Duplex Receptacles (20A)
4. Eco-Mode Switch
Turn ON to increase fuel economy and runtime when the
load is below 2550W (75% load)
5. AC 120V NEMA TT-30 Receptacle (28.3A)
6. Parallel Connection Port
Connect two WEN inverter generators through a parallel
connection kit for a higher output.
7. DC 120V Cigarette-Lighter Style Receptacle
8. DC 5V USB Outlet
1
2
100%
50%
0%
FUEL
2. RUN
OR WARM START
1. START
MANUAL
SHUTOFF
13
3
4
RESET
ECO-MODE
ON
OFF
AC 120V
NEMA 5-20R
CIRCUIT BREAKERS
AC
20A
12
11
9. Grounding Nut
Ground generator to reduce risk of electric shock
10. DC Circuit Breaker (10A)
11. AC Circuit Breaker for NEMA 5-20R (20A)
12. Manual Shutoff Button
Push down for 10 seconds to shutoff generator manu-
ally (see page 23)
13. 3-in-1 Switch
Turn switch to start, run, and automatically shut off the
generator
14. Engine Start Button
Turn switch to "Start" and press button to ignite the en-
gine (see page 17)
15. Auto OFF / Fuel Shutoff
Automatically shuts off generator after fuel in the carbu-
retor is consumed (see page 23)
5
6
PARALLEL CONNECT
DC 12V
NEMA TT-30R
DC12V
5VDC 1A/2.1A
DC 5V USB
ON
OFF
DC
GROUNDING NUT
10A
10
7
8
9
11

Advertisement

Table of Contents
loading

Table of Contents