Download Print this page
Montigo Proflame 2 RX 300 NG Installation & Maintenance Manual
Montigo Proflame 2 RX 300 NG Installation & Maintenance Manual

Montigo Proflame 2 RX 300 NG Installation & Maintenance Manual

Upgrade kit

Advertisement

Quick Links

PROFLAME 2 UPGRADE KIT
RX 200 + RX 300 NG/LP
Upgrade Kit NG/LP Proflame 2
(Basic to Full Load with Remote)
THIS KIT IS FOR USE WITH THE FOLLOWING MODELS:
RX200:
B34DT-2-F : B34 TOP VENT, ELECTRONIC IGNITION, IPI
B34DR-2-F : B34 REAR VENT, ELECTRONIC IGNITION, IPI
B38DT-2-F : B38 TOP VENT, ELECTRONIC IGNITION, IPI
B38DR-2-F : B38 REAR VENT, ELECTRONIC IGNITION, IPI
PL38DFN-F : PL38 , ELECTRONIC IGNITION, IPI
PL38DFL-F : PL38 , ELECTRONIC IGNITION, IPI
PL42DFN-F : PL42 , ELECTRONIC IGNITION, IPI
PL42DFL-F : PL42 , ELECTRONIC IGNITION, IPI
PL52DFN-F : PL52 , ELECTRONIC IGNITION, IPI
PL52DFL-F : PL52 , ELECTRONIC IGNITION, IPI
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury,
death, or property damage.
— Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a qualified
installer, service agency or the gas fitter.
Installation & Maintenance Manual
RX300:
DL6315NI : DL6315, ELECTRONIC IGNITION, IPI
DL6315STNI : DL6315ST, ELECTRONIC IGNITION, IPI
• The installation of this fireplace must be done by a
®
• Check local codes and read all instructions prior to
C
US
qualified and certified gas appliance installer.
installation.
CAUTION
Ensure that all power to the appliance is off at the electrical breaker
or fuse before beginning installation. Ensure gas is turned off at the
shutoff valve before beginning installation.
WARNING
When installing the fireplace - gas lines, fittings, accessories or any
other objects cannot impede the proper movement of the door
buckles.
WARNING
Some materials used in the manufacturing process of this product can
expose you to Benzene which is known in the State of California to
cause cancer and birth defects or other reproductive harm. For more
information go to www.P65warnings.ca.gov
XT0016

Advertisement

loading
Need help?

Need help?

Do you have a question about the Proflame 2 RX 300 NG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Montigo Proflame 2 RX 300 NG

  • Page 1 Installation & Maintenance Manual PROFLAME 2 UPGRADE KIT RX 200 + RX 300 NG/LP Upgrade Kit NG/LP Proflame 2 (Basic to Full Load with Remote) THIS KIT IS FOR USE WITH THE FOLLOWING MODELS: RX200: RX300: DL6315NI : DL6315, ELECTRONIC IGNITION, IPI B34DT-2-F : B34 TOP VENT, ELECTRONIC IGNITION, IPI DL6315STNI : DL6315ST, ELECTRONIC IGNITION, IPI B34DR-2-F : B34 REAR VENT, ELECTRONIC IGNITION, IPI...
  • Page 2: Table Of Contents

    A. Disconnect Control Module and Harness: .........3 This upgrade kit contains the necessary components for field upgrade B. Stepper Motor Installation: ..............3 of an approved Montigo fireplace from Proflame 2 basic control C. Control Module Installation: ..............4 system to Full Load with remote.
  • Page 3: Disconnect Control Module And Harness

    Installation RX 200 RX 200 Control Module Disconnect Stepper Motor Installation A. Disconnect Control Module and Harness: B. Stepper Motor Installation 1. Disconnect Control Module Powercord from the PPO box. 1. Using a Torx T20 or slotted screw driver, remove the two screws that are attached to the Hi-Low knob on the Gas Control Valve (Figure 7) and discard the screws and the knob.
  • Page 4: Control Module Installation

    Installation RX 200 Control Module Installation 2. Ensure the prefitted rubber gasket is properly positioned (Figure C. Control Module Installation 11 - D). Otherwise, fit the gasket as shown. 1. Position the new control module on the fireplace floor ( the red switch "SW1"...
  • Page 5: Main On/Off Switch Installation

    Installation RX 200 RX 200 ON/OFF Switch Installation Battery Holder Installation D. Main ON/OFF Switch Installation: E. Battery Holder Installation: 1.Position the Main/off Switch bracket on the right leg of the firebox. 1. Secure the battery holder to the fireplace floor using the supplied velcro strips.
  • Page 6: Operation With Backup Battery

    Installation RX 200 RX 200 Operation w/ Backup Battery Operation with MAIN Power F. Operation with Backup Battery: G. Operation with MAIN Power: 1. Install the four supplied AA batteries to the battery holder. Remove the four batteries from the battery holder Plug the Control Module Power cord to PPO box.
  • Page 7: Cpi / Ipi Jumper Cable Installation

    Installation CPI [Continuous Pilot Ignition] / IPI [Intermittent Pilot Ignition] Jumper Cable Installation “Why use CPI mode”? Installing the CPI Jumper Cable There are several reasons why you may choose to use CPI mode. When 1). Open the control box drawer. a flue is cold it can be difficult to light the appliance. It can take a bit of time (particularly on tall vents) to initialize vent action.
  • Page 8 Installation RX300 Control Board upgrade/replace 4. New Board. Adding options to DL units requires control board upgrades for the following Pilot When upgrading the options Distinction control board, Fan Kit DFK-3 the board will be shipped On/Off with the board installed in LED Kit MCLEDDL63 Switch the drawer and with the...
  • Page 9 Installation 5. Feed On/Off switch 6. Feed Fan, LED, PPO, and 9. Place on LED wire on rightside firebox floor with adhesive wire through drawer frame pilot wires through drawer pad. For LED Install instructions see Optional LED kit Install/ frame. Replace instructions Figure 24.e On/Off switch through drawer Figure 24.f Fan, LED, PPO, and pilot wires Figure 24.i LED wire...
  • Page 10 Installation should be carried out in a clean environment. WARNING! This modulating conversion kit must ONLY be applied as part of a conversion kit supplied by montigo for the specific appliance, and type of fuel, being converted. WARNING! Correct operation of the system cannot be guaranteed if the conversion kit or valve has been dropped or has sustained a strong impact.
  • Page 11 Notes XG2021...
  • Page 12 Installation & Maintenance Manual PROFLAME 2 UPGRADE KIT RX 200 NG/LP RX 300 NG/LP XT0016...