SamplexPower EVO-RC Owner's Manual page 56

Remote control for evolution series inverter/charger, appendix a
Table of Contents

Advertisement

SECTION 4 |
4.5.2.10.1 Programming Steps for Parameter "OC PROTECT"
Enter Key
ð
A N Y O P E R A T I N G
S E L E C T
M O D E
S C R E E N
C H A R G E
4.5.2.11 INPUT RECOVERY
This parameter determines how EVO™ will recover when AC input is made available while in "Battery low voltage!"
or "Battery ultra low voltage!" fault conditions (Section 7, Table 7.1, Srl.2). The following 2 options are available under
this parameter:
Option "0=Buffered" (This is the default option)
Option "1=Direct"
When the EVO™ is in "Battery low voltage!" condition (Section 7, Table 7.1, Srl.1) or in "Battery ultra low voltage!"
condition (Section 7, Table 7.1, Srl.2) and if AC input is made available before expiry of time set by parameter "LV CUT
OFF TIME" (Section 4.4.2.11), the "Battery low voltage!" / "Battery ultra low voltage!" fault conditions will be cleared
and EVO Inverter Charger will recover based on the following 2 options:
a) Option 0=Buffered (Default): Under this option, the unit will initially start in "Inverting Mode", synchronize
with the AC input and then transfer to "Charging Mode". However, if a user programs the value of
"BATTERY LOW VOLTAGE" very close to the "Battery ultra low voltage!" fault threshold of 9V for 1 ms for
EVO-2212 / 3012 or 18V for 1 ms for EVO-2224 / 4024 (Section 7, Table 7.1, Srl.2), a larger load / larger
starting surge on the inverter may drag the battery voltage to 9V / 18V or below for 1 ms and trigger "Battery
ultra low voltage!" fault. Under this condition, the user may change to Option 1=Direct
b) Option 1=Direct: Under this option, the unit will directly start in "Charging Mode"
4.5.2.11.1 Programming Steps for Parameter "INPUT RECOVERY"
Enter Key
ð
A N Y O P E R A T I N G
S E L E C T
M O D E
S C R E E N
C H A R G E
4.6 GROUP 3 PARAMETER SET UP: INPUT LOW LIMIT
4.6.1 Programming Ranges and Default Values of Parameters Under Group 3 – INPUT LOW LIMIT
Table 4.5 gives details of programming ranges and default values of parameters under Parameter Group 3 - INPUT LOW
LIMIT. Refer to Fig 4.1 under Section 4.1 for Menu Map for navigating through various parameters under this Group 3.
56 | SAMLEX AMERICA INC.
Parameter Setup
Up Key
ð
G R O U P
S E L E C T
G R O U P
C U R V E
I N P U T
S E T T I N G
(Table 4.4, Parameter Setup Screen No.11)
Up Key
ð
G R O U P
S E L E C T
G R O U P
C U R V E
I N P U T
S E T T I N G
Enter Key
Up Key x 9 times
ð
ð
D E F A U L T
F R E Q
I N P U T
0 =
6 0
H z
Enter Key
Up Key x 10 times
ð
ð
D E F A U L T
F R E Q
I N P U T
0 =
6 0
H z
Enter Key
ð
O C
P R O T E C T
K E Y
I N
P A S S W O R D
0 =
I N V m o d e
0 0 0 0
Password 8052
See Section 4.3.1
Enter Key
ð
R E C O V E R Y
K E Y
I N
P A S S W O R D
0 =
B u f f e r e d
0 0 0 0
Password 8052
See Section 4.3.1
APPENDIX A
ð
I N P U T
O C
P R O T E C T
0 =
I N V m o d e
ð
I N P U T
R E C O V E R Y
0 =
B u f f e r e d