SamplexPower EVO-RC Owner's Manual page 41

Remote control for evolution series inverter/charger, appendix a
Table of Contents

Advertisement

SECTION 4 |
i
INFO
When using Charging Profile options (i) "1=3Stage Type 1" or (ii) "3=2Stage Type1, a nearly fully charged
battery may be overcharged / boil if the programmed duration of "ABSORP TIME" is excessively long. Care
should be taken to determine the time the battery is required to remain in Absorption Stage ("ABSORP TIME")
based on the application and then, set programming parameter "ABSORP TIME" accordingly
Programmable range is 0 – 600 min. Default value is 60 min
4.4.2.19.1 Programming Steps for Parameter "ABSORP TIME"
Enter Key
ð
A N Y O P E R A T I N G
M O D E
S C R E E N
4.4.2.20 ABSORP EXIT AMPS (Table 4.1, Parameter Setup Screen No. 20)
Parameter "ABSORP EXIT AMPS" is used to set the value of the charging current at which the charger will exit Absorption
Stage and transition to Float Stage when the following option for programming parameter "Charging Profile" (See
Section 4.4.2.21) is selected"
2=3 Stage Type 2
Programmable range is 0 – 20A. Default value is 4A
4.4.2.20.1 Programming Steps for Parameter "ABSORP EXIT AMPS"
Enter Key
ð
A N Y O P E R A T I N G
M O D E
S C R E E N
4.4.2.21 CHARGING PROFILE (Table 4.1, Parameter Setup Screen No. 21)
Parameter "CHARGING PROFILE" provides 6 options for Charging Profiles that are designed to cover various charging
requirements for Lead Acid, Nickel-Zinc (Ni-Zn) and Lithium Ion Batteries.
i
INFO
7th Charging Profile i.e. 4-Stage Adaptive Charging Profile for Equalization is also available and can be activated
at any time during charging taking place under 1 of the 6 Charging Profile options given at Section 4.4.2.21
above. Procedure to activate 4-Stage Adaptive Charging Profile for Equalization is described under programming
parameter "EQUALIZE- 4 STAGES" at Section 4.4.2.12
The 6 options under parameter "CHARGING PROFILE" are as follows:
0 = 3 Stage Adaptive (Default)
1 = 3 Stage Type 1
2 = 3 Stage Type 2
Parameter Setup
Enter Key
ð
S E L E C T
G R O U P
B U L K C U R R E N T
C H A R G E
C U R V E
Enter Key
ð
S E L E C T
G R O U P
B U L K C U R R E N T
C H A R G E
C U R V E
Up Key x 18 times
ð
A B S O R P
T I M E
4 0
A
6 0 m i n
Up Key x 19 times
ð
A B S O R P
E X I T
4 0
A
4
3 = 2 Stage Type 1
4 = 2 Stage Type 2
5 = 2 Stage Type 3
Enter Key
ð
K E Y
I N
P A S S W O R D
0 0 0 0
Password 8052
See Section 4.3.1
Enter Key
ð
A M P S
K E Y
I N
P A S S W O R D
A
0 0 0 0
Password 8052
See Section 4.3.1
SAMLEX AMERICA INC. | 41
APPENDIX A
ð
A B S O R P
T I M E
0 6 0 m i n
ð
A B S O R P
E X I T
A M P S
0 4
A