SamplexPower EVO-RC Owner's Manual page 38

Remote control for evolution series inverter/charger, appendix a
Table of Contents

Advertisement

SECTION 4 |
If attempt is made to exit Standby Mode by momentarily pressing the On/Off Key, the following message will be seen
for some time and the screen will revert back to Standby Mode Screen
C H A R G E R O N L Y
I N V E R T E R O F F
For various display screens under this mode, refer to Figs 3.4(a) & 3.4(b)
4.4.2.13.4 Programming Steps for Parameter "MODE"
Enter Key
ð
A N Y O P E R A T I N G
M O D E
S C R E E N
4.4.2.14 ONLINE OPTION (Table 4.1, Parameter Setup Screen No. 14)
This setting is effective only when "On-line" Mode is selected (Parameter "MODE" is set at option "1=On-line". See
Section 4.4.2.13). The default setting is: 0=Option 1. Programming steps are given below:
4.4.2.14.1 Programming Steps for Parameter "ONLINE OPTION"
Enter Key
ð
A N Y O P E R A T I N G
M O D E
S C R E E N
Details of the two options are given below:
0= Option 1 (Default):
The Transfer Relay will be switched ON (energized) if the battery voltage drops to the voltage threshold of "LOW
VOLT ALARM" (Section 4.4.2.8) or lower for sustained period = "GS DETECT TIME" (Section 4.4.2.16). The
EVO™ will change over to "Charging Mode" and qualified AC input from the AC input source will be passed
through to the AC Output and at the same time, the Internal AC Charger will start charging the battery. If an
external Solar Charge Controller is also connected to the External Charging Terminals (3 and 4, Fig 2.1 in the
attached Owner's Manual for EVO-2212/3012/2224/4024), the internal AC Charger will limit the charging
current to a value = (Programmed Value of Bulk Current – Value of Current fed from the external Solar Charge
Controller).
Charging will be carried out till the batteries are charged as follows and then, the Transfer Relay will be de-
energized to exit Charging Mode and revert back to Inverting Mode:
For Parameter "CHARGING PROFILE" (Section 4.4.2.21) set for 3 Stage Charging Profile as per:
o
(i) "Option "0 = 3 Stage Type 0", (ii) Option "1 = 3 Stage Type 1" and (iii) Option "2 = 3 Stage
Type 2"
The Transfer Relay will be de-energized to exit Charging Mode and revert to Inverting Mode
as soon as the battery bank is charged to the voltage threshold set by parameter "FLOATING
VOLTAGE" (Section 4.4.2.4)
For Parameter "CHARGING PROFILE" (Section 4.4.2.21) set for 2 Stage Charging Profile as per
o
"Option "3 = 2 Stage Type 1"
The Transfer Relay will be de-energized to exit Charging Mode and revert to Inverting Mode
when the battery bank is charged to voltage threshold set by parameter "ABSORP VOLTAGE"
38 | SAMLEX AMERICA INC.
Parameter Setup
Enter Key
ð
S E L E C T
G R O U P
B U L K C U R R E N T
C H A R G E
C U R V E
Enter Key
ð
S E L E C T
G R O U P
B U L K C U R R E N T
C H A R G E
C U R V E
Up Key x 12 times
ð
M O D E
4 0
A
0 =
N o r m a l
Up Key x 13 times
ð
O N L I N E O P T I O N
4 0
A
0 =
O p t i o n
Enter Key
ð
K E Y
I N
P A S S W O R D
0 0 0 0
Password 8052
See Section 4.3.1
Enter Key
ð
K E Y
I N
P A S S W O R D
1
0 0 0 0
Password 8052
See Section 4.3.1
APPENDIX A
ð
M O D E
0 =
N o r m a l
ð
O N L I N E O P T I O N
0 =
O p t i o n
1