SamplexPower EVO-RC Owner's Manual page 23

Remote control for evolution series inverter/charger, appendix a
Table of Contents

Advertisement

SECTION 4 |
4.2.1.1 Example for Setting Parameter "BULK CURRENT"
Referring to Parameter Setup Menu Maps at Figs 4.1/ 4.2, it is seen that parameter "BULK CURRENT" appears under
PARAMETER GROUP NO.1 named "CHARGE CURVE" & PARAMETER SETUP SCREENS NO.1 for parameter "BULK
CURRENT".
Example in Fig 4.3 below starts with Inverting Mode Screen (Screen No.1 of 16 screens under "GROUP 2: INVERTING
MODE" - Fig 3.2). After the Enter key is pressed, the Up/Down keys are used to navigate through different "PARAMETER
GROUP NOS." ("PARAMETER GROUP NOS." 1-4 in Fig 4.1 & "PARAMETER GROUP NOS." 5-7 in Fig 4.2). When the
"PARAMETER GROUP"containing the desired parameter is displayed on the LCD (Group 1 in Fig 4.3), the Enter Key is
pressed again to select this "PARAMETER GROUP". When the desired "PARAMETER GROUP NO." is selected, Screen
1 of the sub-menu screens under the selected "PARAMETER GROUP NO." appears ("BULK CURRENT" in example
shown in Fig 4.3). The Up and Down Keys are used to navigate through the individual parameters within the selected
"PARAMETER GROUP NO."
Pressing the Back Key will exit to the previous Menu Level.
i
INFO
There is a 30 second timeout for setting parameters; after 30 seconds the Setting Mode will be cancelled and
the EVO-RC will revert to the Operating Mode Screen associated with current operation.
It is highly recommended to set the EVO™ Date and Time (PARAMETER GROUP NO.6) as this value is used to record
data logging files. (Refer to Section 4.9 for Date and Time set up).
Any Operating Mode
Screen from Fig 3.2 to 3.6
(SAY INVERTING)
I N V E R T I N G
O U T P U T
1 2 0 . 0 0
(The above Operating Mode Screen is
from display screen No.1 of 16 screens
under "GROUP 2: INVERTING MODE"
- Fig 3.2)
NOTE: Parameter Group No.7 Screen
will be displayed only when SD Card
has been inserted
Fig 4.3 Parameter Setup Procedure – Example for Setting "BULK CURRENT"
Parameter Setup
ENTER KEY
ð
PARAMETER
V
ï
GROUP NO.1
BACK KEY
PARAMETER
GROUP NO.2
PARAMETER
GROUP NO.3
PARAMETER
GROUP NO.4
PARAMETER
GROUP NO.5
PARAMETER
GROUP NO.6
PARAMETER
GROUP NO.7
"Parameter Group"
Sub-Menus
ENTER KEY
ð
S E L E C T
G R O U P
C H A R G E
C U R V E
ï
ò ñ
BACK KEY
UP KEY
DOWN KEY
S E L E C T
G R O U P
I N P U T
S E T T I N G
ò ñ
UP KEY
DOWN KEY
S E L E C T
G R O U P
I N P U T
L O W L I M I T
ò ñ
UP KEY
DOWN KEY
S E L E C T
G R O U P
I N P U T
H I G H
L I M I T
ò ñ
UP KEY
DOWN KEY
S E L E C T
G R O U P
O T H E R
F U N C T I O N
ò ñ
UP KEY
DOWN KEY
S E L E C T
G R O U P
T I M E
S E T T I N G
ò ñ
UP KEY
DOWN KEY
S E L E C T
G R O U P
S T O P
S D C A R D
"Parameter Setup"
Screen
(eg. BULK CURRENT)
B U L K C U R R E N T
4 0
A
LEGEND FOR FOR FIG 4.3
Press Up Key to scroll to
ò
UP
higher"PARAMETER GROUP NO." in
KEY
the Menu Map
Press Down Key to scroll to lower
ñ
DOWN
"PARAMETER GROUP NO." in the
KEY
Menu Map
(i) Press Enter Key from any Operating
Mode Screen to go to "PARAMETER
GROUP 1"
(ii) Press Enter Key to select the desired
ð
parameter under the sub-menu for the
ENTER KEY
selected "PARAMETER GROUP NO."
(iii) Press Enter Key to select the new
option/ value of the parameter
ï
Press Back Key
BACK KEY
SAMLEX AMERICA INC. | 23