Download Print this page

Welbilt Frymaster FilterQuick FQE30-T Installation, Operation And Maintenance Manual page 26

Advertisement

3.
Note the temperature on the thermometer or pyrometer. Actual temperature and
pyrometer readings should be within ± 5ºF (3ºC) of each other after allowing the heat to cycle
on and off three (3) times. If the temperature is still out of tolerance, contact a Factory
Authorized Servicer for assistance.
4.5
QUARTERLY CHECKS AND SERVICE
4.5.1
Clean the Frypot and Heating Elements
Never operate the appliance with an empty frypot. The frypot must be filled to the fill
line with water or cooking oil before energizing the elements. Failure to do so will result
in irreparable damage to the elements and may cause a fire.
4.5.2 Replace the O-rings
Replace the O-rings on the filter connection (see Figure 10 in section 3.4.2).
4.5.3 Clean (Boiling Out) the Frypot
During normal usage of your fryer, a deposit of carbonized oil will gradually form on the inside
of the frypot. This film should be periodically removed by following the Clean (boil-out)
procedure Refer to sections 2.3.10 and 2.3.11 of the FQ4000 Controller Operation Manual) for
specific details on setting up the controller for clean (boil-out) operation.
Allow oil to cool to 100ºF (38ºC) or lower before draining to an appropriate container for
disposal.
Never leave the fryer unattended during this process. If the solution overflows, press
the ON/OFF switch to the OFF position immediately.
Ensure that the frypot is completely free of water before filling with oil. When the oil is
heated to cooking temperature, water in the frypot will cause splattering.
DANGER
DANGER
WARNING
DANGER
4-3

Advertisement