Utility Interface With Evolution Control; Evolution Control, Green Communications (Comm) Light - Bryant Evolution Extreme 186CNV Installation Instructions Manual

Variable speed air conditioner with puron refrigerant
Hide thumbs Also See for Evolution Extreme 186CNV:
Table of Contents

Advertisement

186CNV: Installation Instructions

Utility Interface With Evolution Control

The utility curtailment relay should be wired between the two UTIL
connections on the control board for this Evolution Communicating
System (see
Fig.
25). This input allows a power utility device to
interrupt compressor operation during peak load periods. When the
utility sends a signal to shut the system down, the User Interface will
display: "Curtailment Active". See UI installation instructions for setup
details.
Evolution Control, Green Communications (COMM)
Light
A green LED (COMM light) on the outdoor board (see
Fig.
26) indicates
successful communication with the other system products. The green
LED will remain OFF until communication is established. Once a valid
command is received, the green LED will turn ON continuously. If no
communication is received within 2 minutes, the LED will be turned
OFF until the next valid communication.